Difference between revisions of "More resolution studies"

From GlueXWiki
Jump to: navigation, search
m (MC (Magnet on))
m (MC (No magnet))
Line 28: Line 28:
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
 
|-
 
|-
|width="415pt"|[[Image:resmc7030.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2).]]
+
|width="415pt"|[[Image:resmc7030.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2). Line is MC, points are data.]]
 
|width="415pt"|[[Image:resmc5050.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2).]]
 
|width="415pt"|[[Image:resmc5050.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2).]]
 
|-
 
|-
Line 37: Line 37:
 
|-
 
|-
 
|}
 
|}
 
  
 
= MC (Magnet on) =
 
= MC (Magnet on) =

Revision as of 11:36, 24 August 2009

Data (No magnet)

Resolutions (in um) as a function of distance to the wire (in mm) for 90/10.
Resolutions (in um) as a function of distance to the wire (in mm) for 80/20.
Resolutions (in um) as a function of distance to the wire (in mm) for 70/30.
File:Resdat5050.jpg
Resolutions (in um) as a function of distance to the wire (in mm) for 50/50.
File:Res2dat4060.jpg
Resolutions (in um) as a function of distance to the wire (in mm) for 40/60.

MC (No magnet)

Resolutions (in um) as a function of distance to the wire (in mm) for 90/10 (Ar/CO2).
Resolutions (in um) as a function of distance to the wire (in mm) for 80/20 (Ar/CO2).
Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2). Line is MC, points are data.
File:Resmc5050.jpg
Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2).
Resolutions (in um) as a function of distance to the wire (in mm) for 40/60 (Ar/CO2).

MC (Magnet on)

Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2) - minimal drift times up to 620ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 60/40 (Ar/CO2) - minimal drift times up to 670ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2)- minimal drift times up to 790ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 40/60 (Ar/CO2) - minimal drift times up to 920ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 80/20 (CO2/C4H10)- minimal drift times up to 1.3us.