Difference between revisions of "More resolution studies"

From GlueXWiki
Jump to: navigation, search
m
 
m (MC - data (No magnet))
 
(16 intermediate revisions by the same user not shown)
Line 1: Line 1:
= Data =
+
= MC - Data (No magnet) =
 +
{| border="1" cellpadding="2"
 +
|-
 +
|width="415pt"|[[Image:resmc9010.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 90/10 (Ar/CO2).]]
 +
|width="415pt"|[[Image:resmc8020.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 80/20 (Ar/CO2).]]
 +
|-
 +
|}
 +
{| border="1" cellpadding="2"
 +
|-
 +
|width="415pt"|[[Image:resmc7030.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2). Line is MC, points are data.]]
 +
|width="415pt"|[[Image:resmc5050.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2).]]
 +
|-
 +
|}
 +
{| border="1" cellpadding="2"
 +
|-
 +
|width="415pt"|[[Image:resmc4060.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 40/60 (Ar/CO2).]]
 +
|-
 +
|}
  
 +
= MC (Magnet on) =
 +
{| border="1" cellpadding="2"
 +
|-
 +
|width="415pt"|[[Image:resmcmag7030.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2) - minimal drift times up to 620ns.]]
 +
|width="415pt"|[[Image:resmcmag6040.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 60/40 (Ar/CO2) - minimal drift times up to 670ns.]]
 +
|-
 +
|}
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
 
|-
 
|-
|width="415pt"|[[Image:resdat9010.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 90/10.]]
+
|width="415pt"|[[Image:resmcmag5050.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2)- minimal drift times up to 790ns.]]
|width="415pt"|[[Image:resdat8020.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 80/20.]]
+
|width="415pt"|[[Image:resmcmag4060.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 40/60 (Ar/CO2) - minimal drift times up to 920ns.]]
|width="415pt"|[[Image:resdat7030.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 70/30.]]
+
 
|-
 
|-
 
|}
 
|}
 
{| border="1" cellpadding="2"
 
{| border="1" cellpadding="2"
 
|-
 
|-
|width="415pt"|[[Image:resdat5050.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 50/50.]]
+
|width="415pt"|[[Image:resmcmag8020.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 80/20 (CO2/C4H10)- minimal drift times up to 1.3us.]]
|width="415pt"|[[Image:resdat4060.jpg|thumb|none|400px|Resolutions (in um) as a function of distance to the wire (in mm) for 40/60.]]
+
 
|-
 
|-
 
|}
 
|}

Latest revision as of 13:07, 24 August 2009

MC - Data (No magnet)

Resolutions (in um) as a function of distance to the wire (in mm) for 90/10 (Ar/CO2).
Resolutions (in um) as a function of distance to the wire (in mm) for 80/20 (Ar/CO2).
Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2). Line is MC, points are data.
File:Resmc5050.jpg
Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2).
Resolutions (in um) as a function of distance to the wire (in mm) for 40/60 (Ar/CO2).

MC (Magnet on)

Resolutions (in um) as a function of distance to the wire (in mm) for 70/30 (Ar/CO2) - minimal drift times up to 620ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 60/40 (Ar/CO2) - minimal drift times up to 670ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 50/50 (Ar/CO2)- minimal drift times up to 790ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 40/60 (Ar/CO2) - minimal drift times up to 920ns.
Resolutions (in um) as a function of distance to the wire (in mm) for 80/20 (CO2/C4H10)- minimal drift times up to 1.3us.