Minutes-8-21-2014

From GlueXWiki
Revision as of 19:28, 21 August 2014 by Pentchev (Talk | contribs)

Jump to: navigation, search

August 21, 2014 FDC+CDC meeting

Agenda

  1. DAQ (Beni)
  2. CDC status Curved Tracks (Mike, Beni)
  3. FDC status scattering event, horizontal shower event (Lubomir)
  4. Electronics (Chris, Nick)
  5. Engineering (Bill)
    • Chiller
    • Cathode scan (Luke)
  6. Commissioning Wiki Page, CDC, FDC commissioning plan (all)
  7. Other

Instructions for Bluejeans meeting connection

FDC meeting ID: 290664653

Minutes

Participants: Curtis, Naomi (CMU), Sean (NU), Beni, Mike, Luke, Eugene, Chris, Nick, Dave, Bill, Fernando, Sergey, Vlad and Lubomir (JLab).

DAQ

- Beni: testing the latest fADC125 firmware released, works except something goes wrong in the FPGA when setting event number. ROCFDC3 has problems will be excluded for the next run. We want to take data with the magnet on. The top scintillator paddle was moved as high as possible to reduce the filed on the PMTs. Actually, after the meeting Beni and Elton were able to get signals from the scintillator (after increasing the HV) and started the DAQ (FDC+CDC) with the considence trigger.

- Discussions about horizontal trigger. We need to install it back. The upstream paddles can be installed when the traget is out. Instead of the downstream paddles one can use the TOF, but it requires the GTP.

CDC update

- Mike showed curved tracks (linked) in the CDC at 600A magnetic field. Some local curvatures seen can be explained if the drift time is taken into account.

- Fernado: additional ground on the CDC aluminum ring to which the HV is connected has been installed. Expect to reduce the noise significantly. Grounding the HVBs directly will be done as a last resort in it will be done in a different way through the grounding lugs.

FDC update

- Lubomir: by applying timing cuts on the hits from the two cathodes and the wires in a cell, one can reduce the threshold down to 50 fADC units (~4mV). As a result we see now most of the "missing" cathode channels, that have problems with the conductive tape. Of course the resolution will be deteriorated but one can stiil use this information for the pattern recongition. Couple of interesting events are linked above.