Difference between revisions of "Minutes-8-16-2012"
From GlueXWiki
Line 23: | Line 23: | ||
Participants: Eugene, Bill, Dave, Simon, Vlad, Beni, and Lubomir | Participants: Eugene, Bill, Dave, Simon, Vlad, Beni, and Lubomir | ||
− | == | + | == Cathode production == |
+ | |||
+ | - Dave: working on 8 new cathodes to be used in the second package. The bottleneck is the card gluing since we have not decided if we want to change the procedures. | ||
== Cathode corrosion == | == Cathode corrosion == | ||
− | - Lubomir: | + | - Lubomir about the SEM results: On the wire samples some small crystals (~3um) are seen containing sulfur, Olga counted about 25 of these on 2cm wire length; too small quantity to account for the copper damage on the cathodes. On the EPDM surface - no conductivity and very low yield from the microscope - still one see some sulfur on the used EPDM, and much less or nothing on the virgin EPDM and on the prototype EPDM. Dave will check if the virgin and used EPDMs are from the same batch. |
+ | |||
- Three other test experiments are running. One with production cathodes and a wire frame that started more than two weeks ago. Second one with similar samples using the small-scale prototype, running since yesterday when we were able to fix the HV. The third one is the Vlad's experiment using the vacuum chamber (picture linked) with same samples (EPDM, Viton with/without Apiezon) with same gas, but no HV, with some water inside to create moisture, all this heated with a lamp (only during the day) up to 80degC. It started yesterday; we will open the chamber on Monday. | - Three other test experiments are running. One with production cathodes and a wire frame that started more than two weeks ago. Second one with similar samples using the small-scale prototype, running since yesterday when we were able to fix the HV. The third one is the Vlad's experiment using the vacuum chamber (picture linked) with same samples (EPDM, Viton with/without Apiezon) with same gas, but no HV, with some water inside to create moisture, all this heated with a lamp (only during the day) up to 80degC. It started yesterday; we will open the chamber on Monday. |
Revision as of 11:50, 17 August 2012
August 16, 2012 FDC meeting
Agenda
- Cathode production Construction Tracking (Dave)
- Cathode corrosion
- Status [1]
- Possible procedure changes
- Conductive tape technology
- Test results [2], ball counting hist.#1, ball counting hist.#2, ball counting hist.#3, ball counting hist.#4, ball counting hist.#5, ball counting hist.#6
- Procedure changes
- Engineering (Bill)
- Cathode strong-back
- Other: epoxy tests
- Electronics (Chris, Nick)
- PCBs
- TDR, pages 132-145 (Lubomir)
- Other