Line 26: Line 26:
  
 
- Beni created a web page (linked above) for the readiness review. The first part contains a checklist for the review. Eugene commented on the recovery procedures that they have to be in parallel with the acceptance tests. Beni: since we can't anticipate all the problems there must be also a common part explaining in general what we should do in case of unexpected problems. Lubomir: regarding the package assembling and package testing we don't have clear procedures yet. The testing will depend on the results from the first new design chamber. The idea is to build first one chamber with two end windows, to mount it to empty cathode/spacer frames as if it is in the package and to test it. Eugene: the review will be for the production only up to the point of the package assembling. Later we will add the documents for the rest of the procedures.     
 
- Beni created a web page (linked above) for the readiness review. The first part contains a checklist for the review. Eugene commented on the recovery procedures that they have to be in parallel with the acceptance tests. Beni: since we can't anticipate all the problems there must be also a common part explaining in general what we should do in case of unexpected problems. Lubomir: regarding the package assembling and package testing we don't have clear procedures yet. The testing will depend on the results from the first new design chamber. The idea is to build first one chamber with two end windows, to mount it to empty cathode/spacer frames as if it is in the package and to test it. Eugene: the review will be for the production only up to the point of the package assembling. Later we will add the documents for the rest of the procedures.     
 
<!--
 
  
 
== Electronics ==
 
== Electronics ==
Line 35: Line 33:
 
- Chris is working on the PR for the rigid-flex stuffing. We want to have all the flexes (615) populated.  
 
- Chris is working on the PR for the rigid-flex stuffing. We want to have all the flexes (615) populated.  
  
- Beni/Bill contacted the Japanese company (http://www.almit.co.jp/eng/product/sold.html#pb) that made the UVA solder. They   
+
- Beni/Bill contacted the Japanese company (http://www.almit.co.jp/eng/product/sold.html#pb) that made the UVA solder. They don't have the exact same solder but something very similar: KR-19 SHRMA QQ-S-571F Type RMA. UVA used the same except KR-18 that indicates difference in the flux but nobody knows exactly what that number mean. This is a "no-clean" type  and Chris suggested to ask what cleaners can be used for the flux.
 +
 
 +
== Engineering ==
  
== Engineering ==
+
<!--
  
 
- The test wire frame was taken out of the strongback and mounted (relatively loose) on the template jig with lead blocks on the sides to make it flat. The tension went down (page 552) by 10-30%. This is still acceptable but it doesn't represent the real tension when the frames will be mounted in the package. To investigate the flatness of the package Bill is going to use the cathode frames and the gas spacers to mount them as a package and measure the height of this assembly.   
 
- The test wire frame was taken out of the strongback and mounted (relatively loose) on the template jig with lead blocks on the sides to make it flat. The tension went down (page 552) by 10-30%. This is still acceptable but it doesn't represent the real tension when the frames will be mounted in the package. To investigate the flatness of the package Bill is going to use the cathode frames and the gas spacers to mount them as a package and measure the height of this assembly.   

Revision as of 18:57, 3 March 2011

March 3, 2011 FDC meeting

Agenda

  1. Production
    • Blue Crab status (David)
    • Readiness review program (Beni, Dave, Bill)
  2. Electronics (Fernando, Roger)
  3. Engineering (Bill, David)
    • New mounting template
    • Other
  4. Chamber testing
    • "Upside-down" tests (Lubomir)
  5. Other


Minutes

Participants: Bill, Dave, Simon, Chris, Glenn, Eugene, Beni, and Lubomir.

Production

- Dave: There was safety walk-through at Blue Crab; no issues. All the tables needed are inside the clean room except the stringing table. A test PCB ring was glued using old boards and Bill is happy with it. Important is to fill the gaps at the joints where the O-ring is positioned to avoid gas leakage. Test were made with the conductive epoxy we got from CMU and it worked well. So we will use this epoxy to connect the cathode to the ground plane. Will need ~20g (~$80) per plane. Next to be done: checking cathode frame height and the depth of the O-ring grooves.

- Beni created a web page (linked above) for the readiness review. The first part contains a checklist for the review. Eugene commented on the recovery procedures that they have to be in parallel with the acceptance tests. Beni: since we can't anticipate all the problems there must be also a common part explaining in general what we should do in case of unexpected problems. Lubomir: regarding the package assembling and package testing we don't have clear procedures yet. The testing will depend on the results from the first new design chamber. The idea is to build first one chamber with two end windows, to mount it to empty cathode/spacer frames as if it is in the package and to test it. Eugene: the review will be for the production only up to the point of the package assembling. Later we will add the documents for the rest of the procedures.

Electronics

- As of now Allflex plans to produce one set (three panels) per week starting 03/25/11. Eugene: the rate is too low and it will take almost two years. Bill: we would like to have 3 sets per week. We may use students for the foil inspection. We will ask Allflex to increase the production rate.

- Chris is working on the PR for the rigid-flex stuffing. We want to have all the flexes (615) populated.

- Beni/Bill contacted the Japanese company (http://www.almit.co.jp/eng/product/sold.html#pb) that made the UVA solder. They don't have the exact same solder but something very similar: KR-19 SHRMA QQ-S-571F Type RMA. UVA used the same except KR-18 that indicates difference in the flux but nobody knows exactly what that number mean. This is a "no-clean" type and Chris suggested to ask what cleaners can be used for the flux.

Engineering