Difference between revisions of "Minutes-1-5-2012"
From GlueXWiki
Line 24: | Line 24: | ||
== Production == | == Production == | ||
− | - Dave for the last cell of the second package: a field wire was replaced on the wire plane yesterday to be cleaned today, daughter cards were glued on the type-2 cathode today, type-1 cathode is ready. Tomorrow we will have all the parts of the last cell ready for testing and installation. Next cell (for third package): wire frame was laminated, | + | - Dave for the last cell of the second package: a field wire was replaced on the wire plane yesterday to be cleaned today, daughter cards were glued on the type-2 cathode today, type-1 cathode is ready. Tomorrow we will have all the parts of the last cell ready for testing and installation. Next cell (for third package): wire frame was laminated, type-1 cathode ready, working on the flaps for the type-2 cathode. For the nex wire frame lamination we will use a board with the vias not sealed (we have several of this kind); Bill suggested using Hysol to cover the vias right after lamination. |
− | - | + | - The fifth cell of the second package was installed right before the break and was tested this week successfully. It took long time (~10 days) to condition the chamber: Epon didn't dry as usual or gas flow was too low during the break? |
== Engineering == | == Engineering == | ||
− | - Bill | + | - Bill showed pictures for different parts of the cooling system: pump, manifold. The pump is supposed to operate at ~100psi. The coolant (Fluorinert) is heavier (1.73g/cm^3) than watter. |
− | - | + | - Cu tubing: by directly measuring the weight of a tube piece we found the tube is heavier then what was used in the simulations. Later it turned out that the tubing was simulated correctly, according to the specifications for the tube sizes: 4mm OD and 2.79mm ID. For 4mm OD and Cu density of 8.96 g/cm^3 from the weight measurements one gets 2.14mm ID. After the meeting direct ID measurements confirmed the specified 2.79mm. The only explanation so far is that the density of the tube material is higher. |
− | + | ||
− | + | ||
== Electronics == | == Electronics == |
Revision as of 18:34, 5 January 2012
January 5, 2012 FDC meeting
Agenda
- Production Construction Tracking (Dave)
- Production update
- Second package tests (Lubomir)
- Engineering update (Bill)
- Cooling system
- Electronics update (Chris)
- Pre-amp cards
- HV cabling
- Grounding (Lubomir)
- LV cabling Vlad's scheme
- TDR (Simon)
- Other