Difference between revisions of "Mattione Update 11302011"

From GlueXWiki
Jump to: navigation, search
Line 4: Line 4:
 
* DC dE/dx information used for PID is bad, is disabled until fixed.  
 
* DC dE/dx information used for PID is bad, is disabled until fixed.  
 
** DC dE/dx Confidence Level (for protons, similar for K+'s, &pi;<sup>+</sup>'s, and &pi;<sup>-</sup>).  
 
** DC dE/dx Confidence Level (for protons, similar for K+'s, &pi;<sup>+</sup>'s, and &pi;<sup>-</sup>).  
[[Image:Mattione_Update_11162011_DCdEdxConfidenceLevel.gif|thumb|left|600px|protons]]
+
[[Image:Mattione_Update_11162011_DCdEdxConfidenceLevel.gif|thumb|left|500px|protons]]
 
<br style="clear:both;"/>
 
<br style="clear:both;"/>
  
Line 16: Line 16:
 
** &sigma; is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
 
** &sigma; is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
 
{| class="wikitable"
 
{| class="wikitable"
| [[Image:Mattione_Update_11302011_MeandEdxVsBetaGamma_FDCPiPlus.gif|thumb|left|600px|FDC, &pi;<sup>+</sup>, &mu;]]
+
| [[Image:Mattione_Update_11302011_MeandEdxVsBetaGamma_FDCPiPlus.gif|thumb|left|500px|FDC, &pi;<sup>+</sup>, &mu;]]
| [[Image:Mattione_Update_11302011_SigmadEdxVsBetaGamma_FDCPiPlus.gif|thumb|left|600px|FDC, &pi;<sup>+</sup>, &sigma;]]
+
| [[Image:Mattione_Update_11302011_SigmadEdxVsBetaGamma_FDCPiPlus.gif|thumb|left|500px|FDC, &pi;<sup>+</sup>, &sigma;]]
 
|}
 
|}
  
Line 23: Line 23:
 
** &sigma; is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
 
** &sigma; is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
 
{| class="wikitable"
 
{| class="wikitable"
| [[Image:Mattione_Update_11302011_MeandEdxVsBetaGamma_FDCProton.gif|thumb|left|600px|FDC, protons, &mu;]]
+
| [[Image:Mattione_Update_11302011_MeandEdxVsBetaGamma_FDCProton.gif|thumb|left|500px|FDC, protons, &mu;]]
| [[Image:Mattione_Update_11302011_SigmadEdxVsBetaGamma_FDCProton.gif|thumb|left|600px|FDC, protons, &sigma;]]
+
| [[Image:Mattione_Update_11302011_SigmadEdxVsBetaGamma_FDCProton.gif|thumb|left|500px|FDC, protons, &sigma;]]
 
|}
 
|}
  

Revision as of 14:07, 30 November 2011

DC dE/dx Study Overview

Introduction

  • DC dE/dx information used for PID is bad, is disabled until fixed.
    • DC dE/dx Confidence Level (for protons, similar for K+'s, π+'s, and π-).
protons


Procedure

  • Look at reconstructed dE/dx in CDC & FDC (treated separately: different gas mixtures).
    • Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored: truncates Landau distribution to resemble Gaussian distribution.
  • Fit mean and σ of these distributions and use them in calculation of χ2

FDC

  • FDC π+ dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
FDC, π+, μ
FDC, π+, σ
  • FDC protons dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
FDC, protons, μ
FDC, protons, σ

CDC

  • CDC π+ dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
CDC, π+, μ
CDC, π+, σ
  • CDC protons dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
CDC, protons, μ
CDC, protons, σ

CDC Proton Confidence Levels

  • Confidence Level of all protons with # CDC hits >= 6 (# used hits > 3)
CDC, protons, # CDC hits >= 6


  • Confidence Level of protons with varying # of CDC hits used
CDC, protons, # Hits Used = 4
CDC, protons, # Hits Used = 6
CDC, protons, # Hits Used = 8
CDC, protons, # Hits Used = 10
CDC, protons, # Hits Used = 12
CDC, protons, # Hits Used = 14