Difference between revisions of "Mattione Update 11302011"

From GlueXWiki
Jump to: navigation, search
Line 1: Line 1:
 +
== DC dE/dx Study Overview ==
 +
 +
=== Introduction ===
 +
* DC dE/dx information used for PID is bad, is disabled until fixed.
 +
** DC dE/dx Confidence Level (for protons, similar for K+'s, &pi;<sup>+</sup>'s, and &pi;<sup>-</sup>).
 +
[[Image:Mattione_Update_11162011_DCdEdxConfidenceLevel.gif|thumb|left|600px|protons]]
 +
<br style="clear:both;"/>
 +
 +
=== Procedure ===
 +
* Look at reconstructed dE/dx in CDC & FDC (treated separately: different gas mixtures).
 +
** Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored: truncates Landau distribution to resemble Gaussian distribution.
 +
* Fit mean and &sigma; of these distributions and use them in calculation of &chi;<sup>2</sup>
 +
 
== FDC ==
 
== FDC ==
 
* FDC &pi;<sup>+</sup> dE/dx &mu; & &sigma;
 
* FDC &pi;<sup>+</sup> dE/dx &mu; & &sigma;
Line 30: Line 43:
  
 
== CDC Proton Confidence Levels ==
 
== CDC Proton Confidence Levels ==
* All tracks with # CDC hits >= 6
+
* Confidence Level of all protons with # CDC hits >= 6 (# used hits > 3)
 
[[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProton.gif|thumb|left|600px|CDC, protons, # CDC hits >= 6]]
 
[[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProton.gif|thumb|left|600px|CDC, protons, # CDC hits >= 6]]
 
<br style="clear:both;"/>
 
<br style="clear:both;"/>
 +
 +
* Confidence Level of protons with varying # of CDC hits used
 +
{| class="wikitable"
 +
| [[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProtonBin1.gif|thumb|left|600px|CDC, protons, # Hits Used = 4]]
 +
| [[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProtonBin2.gif|thumb|left|600px|CDC, protons, # Hits Used = 6]]
 +
|-
 +
| [[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProtonBin3.gif|thumb|left|600px|CDC, protons, # Hits Used = 8]]
 +
| [[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProtonBin4.gif|thumb|left|600px|CDC, protons, # Hits Used = 10]]
 +
|-
 +
| [[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProtonBin5.gif|thumb|left|600px|CDC, protons, # Hits Used = 12]]
 +
| [[Image:Mattione_Update_11302011_ConfidenceLevel_CDCProtonBin6.gif|thumb|left|600px|CDC, protons, # Hits Used = 14]]
 +
|}

Revision as of 14:04, 30 November 2011

DC dE/dx Study Overview

Introduction

  • DC dE/dx information used for PID is bad, is disabled until fixed.
    • DC dE/dx Confidence Level (for protons, similar for K+'s, π+'s, and π-).
protons


Procedure

  • Look at reconstructed dE/dx in CDC & FDC (treated separately: different gas mixtures).
    • Half of the track hits in each of the FDC/CDC (those with the largest dE/dx) are ignored: truncates Landau distribution to resemble Gaussian distribution.
  • Fit mean and σ of these distributions and use them in calculation of χ2

FDC

  • FDC π+ dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
FDC, π+, μ
FDC, π+, σ
  • FDC protons dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
FDC, protons, μ
FDC, protons, σ

CDC

  • CDC π+ dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
CDC, π+, μ
CDC, π+, σ
  • CDC protons dE/dx μ & σ
    • σ is dependent on amount of information: # hits USED (= 1/2 of total # hits: reject largest dE/dx hits to remove Landau tail)
CDC, protons, μ
CDC, protons, σ

CDC Proton Confidence Levels

  • Confidence Level of all protons with # CDC hits >= 6 (# used hits > 3)
CDC, protons, # CDC hits >= 6


  • Confidence Level of protons with varying # of CDC hits used
CDC, protons, # Hits Used = 4
CDC, protons, # Hits Used = 6
CDC, protons, # Hits Used = 8
CDC, protons, # Hits Used = 10
CDC, protons, # Hits Used = 12
CDC, protons, # Hits Used = 14