Difference between revisions of "Mattione Update 10242011"
From GlueXWiki
(→Summary) |
|||
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | == Procedure == | ||
+ | * Fit David's γ σ<sub>t</sub> Improvement: Make dE, θ map | ||
+ | * Fit the π<sup>-</sup> BCAL σ<sub>t</sub> vs θ in dE bins, will apply improvement % to this resolution. | ||
+ | * Generate, simulate, smear, and reconstruct X(2000) -> b1π events | ||
+ | ** For 1234 Segmentation, disabled BCAL hit t-smear in mc_smear, smear reconstructed shower time as a function of dE & &theta during reconstruction to reach improved resolution. | ||
+ | *** Proton, π<sup>+</sup>'s, π<sup>-</sup>'s all smeared the same. | ||
+ | * Plot Δβ vs p for π<sup>+</sup> candidates to see proton, π<sup>+</sup> separation. | ||
+ | |||
== David's BCAL Photon Time Resolution Studies == | == David's BCAL Photon Time Resolution Studies == | ||
− | * γ BCAL | + | * γ BCAL σ<sub>t</sub> vs. dE (GeV): |
− | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta12Degrees.gif|thumb|left| | + | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta12Degrees.gif|thumb|left|400px]] |
− | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta16Degrees.gif|thumb|left| | + | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta16Degrees.gif|thumb|left|400px]] |
− | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta20Degrees.gif|thumb|left| | + | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta20Degrees.gif|thumb|left|400px]] |
− | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta90Degrees.gif|thumb|left| | + | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolution_Theta90Degrees.gif|thumb|left|400px]] |
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == Time Resolution Segmentation Ratio == | ||
+ | |||
+ | * γ BCAL σ<sub>t_1234</sub> / σ<sub>t_334</sub> vs. dE (GeV): | ||
+ | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolutionRatio.gif|thumb|left|400px]] | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | * Fits to γ BCAL σ<sub>t_1234</sub> / σ<sub>t_334</sub> vs. θ in dE bins: | ||
+ | * Don't trust fits at low-θ, so linearly-interpolate between 12 and 16 degrees. | ||
+ | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolutionRatio_Fits1.gif|thumb|left|400px]] | ||
+ | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolutionRatio_Fits2.gif|thumb|left|400px]] | ||
+ | [[Image:Mattione_Update_10242011_BCALPhotonTimeResolutionRatio_Fits3.gif|thumb|left|400px]] | ||
+ | <br style="clear:both;"/> | ||
+ | |||
+ | == BCAL π<sup>-</sup> 334 Segmentation σ<sub>t</sub> Fits == | ||
+ | * BCAL π<sup>-</sup> 334 Segmentation σ<sub>t</sub> Fits vs. θ in dE bins: | ||
+ | [[Image:Mattione_Update_10242011_BCALPiMinusSigmaT_Fits1.gif|thumb|left|400px]] | ||
+ | [[Image:Mattione_Update_10242011_BCALPiMinusSigmaT_Fits2.gif|thumb|left|400px]] | ||
+ | [[Image:Mattione_Update_10242011_BCALPiMinusSigmaT_Fits3.gif|thumb|left|400px]] | ||
+ | [[Image:Mattione_Update_10242011_BCALPiMinusSigmaT_Fits4.gif|thumb|left|400px]] | ||
+ | [[Image:Mattione_Update_10242011_BCALPiMinusSigmaT_Fits5.gif|thumb|left|400px]] | ||
<br style="clear:both;"/> | <br style="clear:both;"/> | ||
− | == | + | == X(2000) -> b1pi Events, π<sup>+</sup> BCAL Δβ vs p == |
Δβ = β<sub>p</sub> - β<sub>t</sub> = p/sqrt(p*p + m*m) - path/(c*TOF) | Δβ = β<sub>p</sub> - β<sub>t</sub> = p/sqrt(p*p + m*m) - path/(c*TOF) | ||
Latest revision as of 14:15, 24 October 2011
Contents
Procedure
- Fit David's γ σt Improvement: Make dE, θ map
- Fit the π- BCAL σt vs θ in dE bins, will apply improvement % to this resolution.
- Generate, simulate, smear, and reconstruct X(2000) -> b1π events
- For 1234 Segmentation, disabled BCAL hit t-smear in mc_smear, smear reconstructed shower time as a function of dE & &theta during reconstruction to reach improved resolution.
- Proton, π+'s, π-'s all smeared the same.
- For 1234 Segmentation, disabled BCAL hit t-smear in mc_smear, smear reconstructed shower time as a function of dE & &theta during reconstruction to reach improved resolution.
- Plot Δβ vs p for π+ candidates to see proton, π+ separation.
David's BCAL Photon Time Resolution Studies
- γ BCAL σt vs. dE (GeV):
Time Resolution Segmentation Ratio
- γ BCAL σt_1234 / σt_334 vs. dE (GeV):
- Fits to γ BCAL σt_1234 / σt_334 vs. θ in dE bins:
- Don't trust fits at low-θ, so linearly-interpolate between 12 and 16 degrees.
BCAL π- 334 Segmentation σt Fits
- BCAL π- 334 Segmentation σt Fits vs. θ in dE bins:
X(2000) -> b1pi Events, π+ BCAL Δβ vs p
Δβ = βp - βt = p/sqrt(p*p + m*m) - path/(c*TOF)
- X(2000) -> b1pi Events, π+ BCAL Δβ vs p, 334 Segmentation: