=== Determine Smearing ===
 
* '''(Photons fitting, others generating/simulating)''' Fit current BCAL time uncertainties for photons, pions, and protons: make sure they're similar to the uncertainties in David's studies.   
 
* '''(Photons fitting, others generating/simulating)''' Fit current BCAL time uncertainties for photons, pions, and protons: make sure they're similar to the uncertainties in David's studies.   
 
** If they are not: probably due to clustering algorithm(s): '''ASSUME''' that the % of the timing uncertainty improvement is independent of this difference.
 
** If they are not: probably due to clustering algorithm(s): '''ASSUME''' that the % of the timing uncertainty improvement is independent of this difference.
Line 9: Line 9:
 
* Determine time-smearing necessary to reach the improved time resolution, code smearing into BCAL shower reconstruction.   
 
* Determine time-smearing necessary to reach the improved time resolution, code smearing into BCAL shower reconstruction.   
  
* Determine PID cuts for protons & pions (delta-beta vs p) (use datasets generated earlier).   
+
=== Physics Analysis ===
 +
* Determine PID cuts for protons & pions (delta-beta vs p) for both smearing resolutions (use datasets generated earlier).   
  
 
* Generate b1pi events (all vertex z)
 
* Generate b1pi events (all vertex z)

Revision as of 11:45, 12 October 2011

Procedure

Determine Smearing

  • (Photons fitting, others generating/simulating) Fit current BCAL time uncertainties for photons, pions, and protons: make sure they're similar to the uncertainties in David's studies.
    • If they are not: probably due to clustering algorithm(s): ASSUME that the % of the timing uncertainty improvement is independent of this difference.
  • Fit the BCAL time resolution improvement % from the table of David's results as a function of theta (separately for photons, pions, and protons). Energy-dependence comes from the coefficients.
  • (FINISHED) Separately generate single-track events of photons, pions, and protons with the BCAL time smearing disabled (generated at center of target: assume that this is what David did).
  • Determine time-smearing necessary to reach the improved time resolution, code smearing into BCAL shower reconstruction.

Physics Analysis

  • Determine PID cuts for protons & pions (delta-beta vs p) for both smearing resolutions (use datasets generated earlier).
  • Generate b1pi events (all vertex z)
  • Two analyses: one with BCAL time smearing disabled (smear during shower reconstruction), the other with default smearing.
  • Run cooking code to reconstruct events.
  • Perform b1pi analysis, using PID cuts (allow all hypotheses).