Difference between revisions of "Mapping PS results"

From GlueXWiki
Jump to: navigation, search
Line 53: Line 53:
  
 
We looked at gradients dB/B, mostly to determine where an NMR monitoring probe could be installed. (These probes do not tolerate gradient greater than 200 to 600 ppm.)
 
We looked at gradients dB/B, mostly to determine where an NMR monitoring probe could be installed. (These probes do not tolerate gradient greater than 200 to 600 ppm.)
 +
 +
'''2.0T data'''
 +
 +
[[Media:Grad_2.0T.pdf]]  gradients on the y-component of the field,By, for 2.0T. Top left: 2D map (By in blue/red/green, Bz in light blue and Bx in magenta), top right: color plot of By (in mTesla) in function of x and z (cm). Bottom left plot: By gradient along x normalized to By (in 0/00).  Bottom right plot: By gradient along z normalized to By (in 0/00).
 +
  
 
'''1.8T data'''
 
'''1.8T data'''

Revision as of 10:16, 4 April 2014

Data


2D maps

2D (z,x) maps were taken at nominal field (1.8T) for 3 vertical (y) positions (0, +/1 cm), and at 2.0Y for y=0):

1.8T, y=0 2D results: Media: Ps_2d_y0_1.8T.pdf‎ Hall probes 1 (red), 3 (blue) and 5 (magenta) measured By. Probe 2 (green) measured Bx, probe 4 (light blue) measured Bz.

1.8T, y=+1cm 2D results: Media: Ps_2d_yp1_1.8T.pdf‎. All Hall probes measured By.

1.8T, y=-1cm 2D results:Media: Ps_2d_ym1_1.8T.pdf‎. All Hall probes measured By.

2.0T, y=0 2D results: Media: Ps_2d_y0_2.0T.pdf‎ Hall probes 1 (red), 2 (green), and 3 (blue) measured By. Probe and 5 (magenta) measured Bx, probe 4 (light blue) measured Bz.


1D maps

1D maps, along z, were taken at 3 field values: 2.0T, 1.5T and 1.0T for 3 transverse (x) positions, at at x=0 only for 1.8T.

2.0, x=0 result (Hall probes measured By): Media: Ps_1dz_2.0T.pdf‎

2.0, x=-10cm result (Hall probes measured By):Media:Ps_1dz_xp10_2.0T.pdf

2.0, x=+10cm result (Hall probes measured By):Media:Ps_1dz_xm10_2.0T.pdf


1.8T, x=0 result (Hall probes measured By): Media: Ps_1dz_1.8T.pdf‎


1.5, x=0 result (Hall probes measured By): Media: Ps_1dz_1.5T.pdf‎

1.5, x=-10cm result (Hall probes measured By): Media:Ps_1dz_xp5_1.5T.pdf

1.5, x=+5cm result (Hall probes measured By):Media:Ps_1dz_xm10_1.5T.pdf


1.0, x=0 result (Hall probes measured By): Media: Ps_1dz_1.0T.pdf‎

1.0, x=-10cm result (Hall probes measured By): Media: Ps_1dz_xp5_1.0T.pdf‎

1.0, x=+5cm result (Hall probes measured By): Media: Ps_1dz_xm10_1.0T.pdf‎



Gradient study

We looked at gradients dB/B, mostly to determine where an NMR monitoring probe could be installed. (These probes do not tolerate gradient greater than 200 to 600 ppm.)

2.0T data

Media:Grad_2.0T.pdf gradients on the y-component of the field,By, for 2.0T. Top left: 2D map (By in blue/red/green, Bz in light blue and Bx in magenta), top right: color plot of By (in mTesla) in function of x and z (cm). Bottom left plot: By gradient along x normalized to By (in 0/00). Bottom right plot: By gradient along z normalized to By (in 0/00).


1.8T data

Media:Grad_1.8T.pdf gradients on the y-component of the field,By, for 1.8T. Top left: 2D map (By in purple/red/blue, Bz in light blue and Bx in green), top right: color plot of By (in mTesla) in function of x and z (cm). Bottom left plot: By gradient along x normalized to By (in 0/00). Bottom right plot: By gradient along z normalized to By (in 0/00).

Media:Grad_1.8T_zoom1.pdf Same as above but zoomed with -10cm<z<+45cm.

Media:Grad_1.8T_zoom2.pdf Same as above but zoomed with -10cm<z<+20cm and normalized gradients are in ppm.