Difference between revisions of "Inspection with an electron microscope II"

From GlueXWiki
Jump to: navigation, search
m
m
Line 10: Line 10:
 
The relative X-ray analysis of a normal area gave three peaks C, Al, and O. The magnitude of the peaks compared as
 
The relative X-ray analysis of a normal area gave three peaks C, Al, and O. The magnitude of the peaks compared as
 
C > Al > O
 
C > Al > O
 +
 +
=== Under source (irradiated) ===
 +
{| border="1" cellpadding="2"
 +
|-
 +
|width="415pt"|[[Image:stone-source-500um.jpg|thumb|none|400px|Stone kapton straw that was irradiated (500um scale).]]
 +
|width="415pt"|[[Image:stone-source-20um.jpg|thumb|none|400px|Stone kapton straw that was irradiated (20um scale).]]
 +
|width="415pt"|[[Image:stone-source-5um.jpg|thumb|none|400px|Stone kapton straw that was irradiated (5um scale).]]
 +
|-
 +
|}
 +
The relative X-ray analysis of a normal area gave three peaks C, Al, and O. The magnitude of the peaks compared as
 +
C > Al > O . The X-ray analysis of a dark spot gave C = 0 > Al. Also the darker the spot the more O present.

Revision as of 02:57, 12 March 2010

Stone kapton straw

Pristine

Stone kapton straw that was never used (500um scale).
Stone kapton straw that was never used (20um scale).
Stone kapton straw that was never used (5um scale).

The relative X-ray analysis of a normal area gave three peaks C, Al, and O. The magnitude of the peaks compared as C > Al > O

Under source (irradiated)

Stone kapton straw that was irradiated (500um scale).
Stone kapton straw that was irradiated (20um scale).
Stone kapton straw that was irradiated (5um scale).

The relative X-ray analysis of a normal area gave three peaks C, Al, and O. The magnitude of the peaks compared as C > Al > O . The X-ray analysis of a dark spot gave C = 0 > Al. Also the darker the spot the more O present.