Testing Infiniband in Rack Room

Setup

  • Have 4 nodes, 16 cores each.
  • Each node has one GBit and one Infiniband port.
  • Infiniband switch rated at 20 Gbit/sec.
  • Running IP over Infiniband, which decreases effective throughput.
  • Run ET system and event producer on one node, run remote consumers on the others.
  • Event producer continually reads from file and inserts events into ET system.
  • Some consumers just get events and dump them (blaster mode), others process the events.
  • Note: when using Ethernet instead of IB got about 95% bandwidth of a Gbit link (950 Mbits/sec).


Observations

  • Single (local) producer can insert events at 380 kHz, avg event size about 7.4 kBytes.
    • producer uses 98% of one core, et system uses 8%.
  • Single remote consumer running in blaster mode gets events at 74 kHz (4.4 Gbit/s), 75% cpu.
    • producer 25%, et 23%.
  • Two consumers 148 kHz aggregate (8.8 Gbit/s), 75% cpu.
    • producer 48%, et 42%.
  • Three consumers 188 kHz (11.1 Gbit/s), 63% cpu.
    • producer 60%, et 58%.