New Note 15
+
Present:
 +
* '''FSU''': Sasha Ostrovidov
 +
* '''JLab''': Hovanes Egiyan, Mark Ito (chair), Yi Qiang, Sascha Somov, Simon Taylor, Beni Zihlmann
  
fsu sasha
+
==Status of the Prototype==
jlab mark, beni, hovanes, yi, sascha, simon
+
  
check on crate
+
* Mark needs to check on getting a crate for FSU.
different idea
+
* Paul has been thinking of a different geometry for the TOF, to aid mechanical construction and support. The principal change would be to go from 6 cm wide counters to 8 cm. This would allow all of the phototubes to lie on the same plane; in the 6 cm design, the &mu;-metal shield would cause interference if the tubes were co-planar. Space between the tubes be used for a support structure. Some implications:
go from 6 cm to 8 cm
+
*# The beam hole bigger would be bigger.
beam hole bigger
+
*# The double-hit probability would be higher.
double hit probability higher
+
*# The rate on the inner counters might increase (or decrease).
∘ running monte carlo to see effect
+
*# We would likely lose light with a wider paddle.
lose light with wider paddle, wider than PMT
+
** Sasha O. is running Monte Carlo to study the effect.
∘ fit tubes side by side, mu metal shield was causing interference
+
* FSU is exploring getting equipment to use UV-curing glue, as suggested by Beni at the last meeting. They have been talking to the Detector Meisters (Brian Cross and Carl Zorn) and folks in Hall C on their experience. A system would cost a few thousand dollars.
exploring getting UV curing glue
+
** JLab, groups, several K$
JLab, groups, several K$
+
** Brian and Carl, Hall C group
Brian and Carl, Hall C group
+
* The prototype is taking data. The data has not been analyzed completely yet. There are some mysteries that Sasha is working to understand.
prototype taking data, not analyzed completely yet, some issues with current set-up
+
* A Hamamatsu PMT was shipped to JLab from FSU. It should arrive soon.
+
  
shipping pmt to jlab
+
==Status of the Contract==
 +
 
 +
Mark showed [[Private:Notes on the TOF Construction Contract|a wiki page]] listing items needed to put a construction contract into place. Beni commented on his experience working on the contract with CMU.

Latest revision as of 23:18, 31 March 2015

Location, Time

Friday, January 21, 2011
2:00 pm EST
JLab: CEBAF Center, Room F326/7

Agenda

  1. Announcements
    • Meeting time ok?
  2. Minutes from the last meeting
  3. Prototype Status
  4. Contract status

Communication

Videoconference

  1. ESNet: 8542553
  2. EVO: EVO site

Telephone

  1. dial:
  2. enter access code followed by the # sign: 3421244#

Slides

Talks can be deposited in the directory /group/halld/www/halldweb/html/talks/2011-1Q on the JLab CUE. This directory is accessible from the web at https://halldweb.jlab.org/talks/2011-1Q/ .

Minutes

Present:

  • FSU: Sasha Ostrovidov
  • JLab: Hovanes Egiyan, Mark Ito (chair), Yi Qiang, Sascha Somov, Simon Taylor, Beni Zihlmann

Status of the Prototype

  • Mark needs to check on getting a crate for FSU.
  • Paul has been thinking of a different geometry for the TOF, to aid mechanical construction and support. The principal change would be to go from 6 cm wide counters to 8 cm. This would allow all of the phototubes to lie on the same plane; in the 6 cm design, the μ-metal shield would cause interference if the tubes were co-planar. Space between the tubes be used for a support structure. Some implications:
    1. The beam hole bigger would be bigger.
    2. The double-hit probability would be higher.
    3. The rate on the inner counters might increase (or decrease).
    4. We would likely lose light with a wider paddle.
    • Sasha O. is running Monte Carlo to study the effect.
  • FSU is exploring getting equipment to use UV-curing glue, as suggested by Beni at the last meeting. They have been talking to the Detector Meisters (Brian Cross and Carl Zorn) and folks in Hall C on their experience. A system would cost a few thousand dollars.
    • JLab, groups, several K$
    • Brian and Carl, Hall C group
  • The prototype is taking data. The data has not been analyzed completely yet. There are some mysteries that Sasha is working to understand.
  • A Hamamatsu PMT was shipped to JLab from FSU. It should arrive soon.

Status of the Contract