Difference between revisions of "Crystal Radiator Goniometer"

From GlueXWiki
Jump to: navigation, search
m (Jonesrt moved page Radiator system to Crystal Radiator Goniometer: devote this page purely to the goniometer, move crystal spec to page about crystals)
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
*[[Specification for diamond crystal radiator]]
 
 
*[[Specification for goniometer|Specification for the crystal goniometer]]
 
*[[Specification for goniometer|Specification for the crystal goniometer]]
 +
*[[Media:goniometer_tests-11-2013.pdf|Actual specifications and performance of the Hall D goniometer]]
 +
*[[Media:URS-B_Data_Sheet_MC.PDF|Datasheet for the goniometer target mount ring Newport URS-150B]]
 +
* Design drawings for [[Media:diamond_support_ring.pdf|the diamond mount support ring]] and [[Media:diamond_mount_bar.pdf|the diamond mount support bar]]
 +
* [[Instructions for goniometer expert operations]]
  
 
<table>
 
<table>
Line 13: Line 16:
 
     <td width="400" align="center">[[Image:goniometer_expanded.png|350px]]
 
     <td width="400" align="center">[[Image:goniometer_expanded.png|350px]]
 
     <br/>Figure 4. Same 3D CAD model at expanded scale</td>
 
     <br/>Figure 4. Same 3D CAD model at expanded scale</td>
</tr><tr valign="bottom" height="400">
 
    <td width="400" align="center">[[Image:goniometer_without_diamonds.png|350px]]
 
    <br/>Figure 2. Same CAD model from another angle</td>
 
    <td width="400" align="center">[[Image:goniometer_with_diamonds.png|350px]]
 
    <br/>Figure 2. Same CAD model from another angle</td>
 
 
</tr><tr valign="bottom">
 
</tr><tr valign="bottom">
     <td width="400" align="center">[[Image:vacuum_tank.png|350px]]
+
     <td width="400" height="320" align="center">[[Image:goniometer_without_diamonds.png|350px]]
     <br/>Figure 2. Same CAD model from another angle</td>
+
    <br/>Figure 5. View of goniometer target region</td>
     <td width="400" align="center">[[Image:diamond_mount_concept.png|350px]]
+
    <td width="400"  height="320" align="center">[[Image:goniometer_with_diamonds.png|350px]]
     <br/>Figure 2. Same CAD model from another angle</td>
+
    <br/>Figure 6. Goniometer target region with diamond mount installed</td>
 +
</tr><tr valign="bottom">
 +
    <td width="400" height="320" align="center">[[Image:vacuum_tank.png|350px]]
 +
     <br/>Figure 7. Goniometer with vacuum cover installed</td>
 +
     <td width="400" height="320" align="center">[[Image:diamond_mount_concept.png|350px]]
 +
     <br/>Figure 8. Conceptual drawing of diamond holder</td>
 
</tr></table>
 
</tr></table>
 
URS-B_Data_Sheet_MC.PDF
 
[[Media:goniometer_tests-11-2013.pdf|Actual specifications and performance of the Hall D goniometer]]
 

Latest revision as of 11:22, 15 March 2016

Goniometer model3d 1.png
Figure 1. CAD model of the Newport crystal goniometer
Goniometer model3d 2.png
Figure 2. Same CAD model from another angle
Goniometer fullview.png
Figure 3. 3D CAD model installed in beamline
Goniometer expanded.png
Figure 4. Same 3D CAD model at expanded scale
Goniometer without diamonds.png
Figure 5. View of goniometer target region
Goniometer with diamonds.png
Figure 6. Goniometer target region with diamond mount installed
Vacuum tank.png
Figure 7. Goniometer with vacuum cover installed
Diamond mount concept.png
Figure 8. Conceptual drawing of diamond holder