Difference between revisions of "Crystal Radiator Goniometer"

From GlueXWiki
Jump to: navigation, search
Line 15: Line 15:
 
</tr><tr valign="bottom">
 
</tr><tr valign="bottom">
 
     <td width="400" height="320" align="center">[[Image:goniometer_without_diamonds.png|350px]]
 
     <td width="400" height="320" align="center">[[Image:goniometer_without_diamonds.png|350px]]
     <br/>Figure 2. Same CAD model from another angle</td>
+
     <br/>Figure 5. View of goniometer target region</td>
 
     <td width="400"  height="320" align="center">[[Image:goniometer_with_diamonds.png|350px]]
 
     <td width="400"  height="320" align="center">[[Image:goniometer_with_diamonds.png|350px]]
     <br/>Figure 2. Same CAD model from another angle</td>
+
     <br/>Figure 6. Goniometer target region with diamond mount installed</td>
 
</tr><tr valign="bottom">
 
</tr><tr valign="bottom">
 
     <td width="400" height="320" align="center">[[Image:vacuum_tank.png|350px]]
 
     <td width="400" height="320" align="center">[[Image:vacuum_tank.png|350px]]
     <br/>Figure 2. Same CAD model from another angle</td>
+
     <br/>Figure 7. Goniometer with vacuum cover installed</td>
 
     <td width="400" height="320" align="center">[[Image:diamond_mount_concept.png|350px]]
 
     <td width="400" height="320" align="center">[[Image:diamond_mount_concept.png|350px]]
     <br/>Figure 2. Same CAD model from another angle</td>
+
     <br/>Figure 8. Conceptual drawing of diamond holder</td>
 
</tr></table>
 
</tr></table>
  
 
URS-B_Data_Sheet_MC.PDF  
 
URS-B_Data_Sheet_MC.PDF  
 
[[Media:goniometer_tests-11-2013.pdf|Actual specifications and performance of the Hall D goniometer]]
 
[[Media:goniometer_tests-11-2013.pdf|Actual specifications and performance of the Hall D goniometer]]

Revision as of 14:08, 8 July 2014

Goniometer model3d 1.png
Figure 1. CAD model of the Newport crystal goniometer
Goniometer model3d 2.png
Figure 2. Same CAD model from another angle
Goniometer fullview.png
Figure 3. 3D CAD model installed in beamline
Goniometer expanded.png
Figure 4. Same 3D CAD model at expanded scale
Goniometer without diamonds.png
Figure 5. View of goniometer target region
Goniometer with diamonds.png
Figure 6. Goniometer target region with diamond mount installed
Vacuum tank.png
Figure 7. Goniometer with vacuum cover installed
Diamond mount concept.png
Figure 8. Conceptual drawing of diamond holder

URS-B_Data_Sheet_MC.PDF Actual specifications and performance of the Hall D goniometer