Comparison of radiation damage between FLUKA and Geant

From GlueXWiki
Revision as of 10:46, 1 October 2010 by Georgek (Talk | contribs)

Jump to: navigation, search
  • Photon energy spectrum used in the simulations (photon flux corresponds to high-luminosity run)

Photon spectrum.jpg

  • Silicon damage function used by FLUKA

Damage function.jpg

  • Particle spectra through the SiPM
RADCON GEANT
FLUKA


FLUKA


  • Particle fluences around barrel calorimeter in terms of 1-MeV equivalent neutrons in Si
FLUKA. Beam power at the target = 0.704 W
FLUKA. Beam power at the target = 0.704 W


  • Total 1-MeV (Si) neutron equivalent fluence in Si PM plane
FLUKA. Si PM limited by two circles with radii of 65 cm and 90 cm


  • Particle fluences in Hall D in terms of 1-MeV equivalent neutrons in Si
FLUKA. Beam power at the target = 0.704 W
FLUKA. Beam power at the target = 0.704 W


  • Particles per cm^2 per second in terms of 1-MeV neutron equivalent in Si estimated with FLUKA simulation (Photon beam power at target = .704 W)
Total Neutrons Protons Pions Electrons Positrons
24.7 ± 1.1 19.5 ± 0.9 1.8 ± 0.1 2.0 ± 0.1 0.9 ± 0.1 0.3 ± 0.1
  • Neutron flux in terms of 1-MeV equivalent neutrons in Si estimated with Geant simulation: 30.5 cm^-2 sec^-1.