Difference between revisions of "Comparison of radiation damage between FLUKA and Geant"
From GlueXWiki
Line 9: | Line 9: | ||
[[Image:n_p_spectra.jpg|400px|thumb|left| FLUKA ]] | [[Image:n_p_spectra.jpg|400px|thumb|left| FLUKA ]] | ||
<br clear=all> | <br clear=all> | ||
− | [[Image: | + | [[Image:particle_spectra.jpg|400px|thumb|left| FLUKA ]] |
<br clear=all> | <br clear=all> | ||
− | * Particle fluences around barrel calorimeter | + | * Particle fluences around barrel calorimeter (1-MeV neutron equivalent in Si) |
[[Image:total_bcal.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | [[Image:total_bcal.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | ||
[[Image:neut_bcal.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | [[Image:neut_bcal.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | ||
<br clear=all> | <br clear=all> | ||
− | * Total 1-MeV | + | * Total fluence (1-MeV neutron equivalent in Si) in Si PM plane |
[[Image:XY_SiPM.jpg|450px|thumb|left| FLUKA. Si PM limited by two circles with radii of 65 cm and 90 cm ]] | [[Image:XY_SiPM.jpg|450px|thumb|left| FLUKA. Si PM limited by two circles with radii of 65 cm and 90 cm ]] | ||
<br clear=all> | <br clear=all> | ||
− | * Particle fluences | + | * Particle fluences (1-MeV neutron equivalent in Si) in Hall D |
[[Image:total_halld.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | [[Image:total_halld.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | ||
[[Image:neut_halld.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | [[Image:neut_halld.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]] | ||
Line 36: | Line 36: | ||
| Positrons | | Positrons | ||
|- | |- | ||
− | | 22. | + | | 22.91 ± 0.18 |
− | | 18. | + | | 18.04 ± 0.12 |
− | | 1.72 ± 0. | + | | 1.72 ± 0.03 |
− | | 1. | + | | 1.80 ± 0.01 |
− | | 1. | + | | 1.0 ± 0.2 |
| 0.19 ± 0.03 | | 0.19 ± 0.03 | ||
|} | |} |
Revision as of 10:39, 5 November 2010
- Photon energy spectrum used in the simulations (photon flux corresponds to high-luminosity run)
- Silicon damage function used by FLUKA
- Particle spectra through the SiPM
- Particle fluences around barrel calorimeter (1-MeV neutron equivalent in Si)
- Total fluence (1-MeV neutron equivalent in Si) in Si PM plane
- Particle fluences (1-MeV neutron equivalent in Si) in Hall D
- Particles per cm^2 per second in terms of 1-MeV neutron equivalent in Si estimated with FLUKA simulation (Photon beam power at target = .704 W)
Total | Neutrons | Protons | Pions | Electrons | Positrons |
22.91 ± 0.18 | 18.04 ± 0.12 | 1.72 ± 0.03 | 1.80 ± 0.01 | 1.0 ± 0.2 | 0.19 ± 0.03 |
- Neutron flux in terms of 1-MeV equivalent neutrons in Si estimated with Geant simulation: 30.5 cm^-2 sec^-1.
- FLUKA geometry and input files: http://www.jlab.org/~georgek/halld/