Difference between revisions of "Comparison of radiation damage between FLUKA and Geant"

From GlueXWiki
Jump to: navigation, search
Line 7: Line 7:
 
* Particle spectra through the SiPM
 
* Particle spectra through the SiPM
 
[[Image:geant_spectrum.jpg|400px|thumb|left| RADCON  GEANT ]]
 
[[Image:geant_spectrum.jpg|400px|thumb|left| RADCON  GEANT ]]
[[Image:spec_neut_prot.jpg|400px|thumb|left| FLUKA ]]
+
[[Image:n_p_spectra.jpg|400px|thumb|left| FLUKA ]]
 
<br clear=all>
 
<br clear=all>
[[Image:spec_part.jpg|400px|thumb|left| FLUKA ]]
+
[[Image:.particle_spectra.jpg|400px|thumb|left| FLUKA ]]
 
<br clear=all>
 
<br clear=all>
  
 
* Particle fluences around barrel calorimeter in terms of 1-MeV equivalent neutrons in Si
 
* Particle fluences around barrel calorimeter in terms of 1-MeV equivalent neutrons in Si
[[Image:total_eq_fl.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
+
[[Image:total_bcal.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
[[Image:neut_eq_fl.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
+
[[Image:neut_bcal.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
 
<br clear=all>
 
<br clear=all>
  
 
* Total 1-MeV (Si) neutron equivalent fluence in Si PM plane
 
* Total 1-MeV (Si) neutron equivalent fluence in Si PM plane
[[Image:sipm_total_eq_fl.jpg|450px|thumb|left| FLUKA. Si PM limited by two circles with radii of 65 cm and 90 cm ]]
+
[[Image:XY_SiPM.jpg|450px|thumb|left| FLUKA. Si PM limited by two circles with radii of 65 cm and 90 cm ]]
 
<br clear=all>
 
<br clear=all>
  
 
* Particle fluences in Hall D in terms of 1-MeV equivalent neutrons in Si
 
* Particle fluences in Hall D in terms of 1-MeV equivalent neutrons in Si
[[Image:hall_total_eq_fl.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
+
[[Image:total_halld.jpg|500px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
[[Image:hall_neut_eq_fl.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
+
[[Image:neut_halld.jpg|450px|thumb|left| FLUKA. Beam power at the target = 0.704 W ]]
 
<br clear=all>
 
<br clear=all>
  

Revision as of 10:34, 5 November 2010

  • Photon energy spectrum used in the simulations (photon flux corresponds to high-luminosity run)

Photon spectrum.jpg

  • Silicon damage function used by FLUKA

Damage function.jpg

  • Particle spectra through the SiPM
RADCON GEANT
FLUKA



  • Particle fluences around barrel calorimeter in terms of 1-MeV equivalent neutrons in Si
FLUKA. Beam power at the target = 0.704 W
FLUKA. Beam power at the target = 0.704 W


  • Total 1-MeV (Si) neutron equivalent fluence in Si PM plane
FLUKA. Si PM limited by two circles with radii of 65 cm and 90 cm


  • Particle fluences in Hall D in terms of 1-MeV equivalent neutrons in Si
FLUKA. Beam power at the target = 0.704 W
FLUKA. Beam power at the target = 0.704 W


  • Particles per cm^2 per second in terms of 1-MeV neutron equivalent in Si estimated with FLUKA simulation (Photon beam power at target = .704 W)
Total Neutrons Protons Pions Electrons Positrons
22.95 ± 0.18 18.07 ± 0.13 1.72 ± 0.02 1.81 ± 0.01 1.01 ± 0.20 0.19 ± 0.03
  • Neutron flux in terms of 1-MeV equivalent neutrons in Si estimated with Geant simulation: 30.5 cm^-2 sec^-1.