Difference between revisions of "Cables and Crates"

From GlueXWiki
Jump to: navigation, search
(VXS crates connected to the FCAL2 insert region)
Line 27: Line 27:
 
* 108 ADC channels in each of four crates are connected to the insert region
 
* 108 ADC channels in each of four crates are connected to the insert region
 
* 238 ADC channels are used in each crate
 
* 238 ADC channels are used in each crate
 +
 +
== Possible rearranging of cables  ==
 +
 +
* Move 108 channels in the rocfcal2 (rocfcal8)  crate connected to the insert to the rocfcal5 (rocfcal11) crate. The total number of channels in this crate: 108 + 108 = 216 (connect to 14 FADCs), see Fig. 1
 +
* Move 126 channels in the rocfcal5 (rocfcal11)  crate connected to the insert to the rocfcal2 (rocfcal8) crate. The total number of channels in this
 +
crate: 130 (remaining) + 126 = 256 (connect to 16 FADCs).

Revision as of 10:23, 26 October 2022

Calorimeter Layout

VXS crate layout

VXS crates connected to the FCAL2 insert region

  • Blue region corresponds to ADC channels connected to the FCAL2 insert region (21x21 lead glass modules). Yellow boxes correspond to channels connected to the region outside the insert.
  • 108 ADC channels in each of four crates are connected to the insert region
  • 238 ADC channels are used in each crate

Possible rearranging of cables

  • Move 108 channels in the rocfcal2 (rocfcal8) crate connected to the insert to the rocfcal5 (rocfcal11) crate. The total number of channels in this crate: 108 + 108 = 216 (connect to 14 FADCs), see Fig. 1
  • Move 126 channels in the rocfcal5 (rocfcal11) crate connected to the insert to the rocfcal2 (rocfcal8) crate. The total number of channels in this

crate: 130 (remaining) + 126 = 256 (connect to 16 FADCs).