Difference between revisions of "CDC recent run drift times"

From GlueXWiki
Jump to: navigation, search
Line 2: Line 2:
  
 
<h2>Run 2451</h2>
 
<h2>Run 2451</h2>
 +
Last run of 2014
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
 
|+ Hit thresholds 180-100-25, window 44-150
 
|+ Hit thresholds 180-100-25, window 44-150
Line 12: Line 13:
 
Garfield 5475-4525 Ar-CO2 has tmax ~560ns
 
Garfield 5475-4525 Ar-CO2 has tmax ~560ns
  
 +
<h2>Run 2551</h2>
 +
After disengaging the alcohol bubbler. March 2-3 2015
 +
 +
<h2>Run 2560</h2>
 +
After changing the CO2 gas factor from 0.773 to 0.74
 +
 +
<h2>Run 2616</h2>
 +
After changing the gas mixer MFCs from master/slave to independent, March 11
 +
 
<h2>Run 2617</h2>
 
<h2>Run 2617</h2>
 +
March 11
 
{| border="0" cellpadding="2"  
 
{| border="0" cellpadding="2"  
 
|+ Hit thresholds 180-100-25, window 44-150
 
|+ Hit thresholds 180-100-25, window 44-150
Line 32: Line 43:
 
|[[Image:cdc_run2619_ped.png|thumb|x200px|pedestal]]
 
|[[Image:cdc_run2619_ped.png|thumb|x200px|pedestal]]
 
|}
 
|}
 +
 +
<h2>Run 2644</h2>
 +
After moving CO2 controller from ch2 to ch4 and decreasing sparsification thresholds
 +
 +
<h2>Run 2649</h2>
 +
After returning CO2 controller from ch4 to ch2

Revision as of 15:37, 26 March 2015

Fitted drift time function to straws in run 2451, picked straws with tmax slope < 30, used same straws for subsequent runs

Run 2451

Last run of 2014

Hit thresholds 180-100-25, window 44-150
Drift time fit straws with param 6 < 30
zoomed in
max amplitude - pedestal
pedestal

Garfield 5475-4525 Ar-CO2 has tmax ~560ns

Run 2551

After disengaging the alcohol bubbler. March 2-3 2015

Run 2560

After changing the CO2 gas factor from 0.773 to 0.74

Run 2616

After changing the gas mixer MFCs from master/slave to independent, March 11

Run 2617

March 11

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Garfield 5200-4800 Ar-CO2 has tmax ~ 595ns

Run 2619

Hit thresholds 180-100-25, window 44-150
Drift time fit
zoomed in
max amplitude - pedestal
pedestal

Run 2644

After moving CO2 controller from ch2 to ch4 and decreasing sparsification thresholds

Run 2649

After returning CO2 controller from ch4 to ch2