Proposed Tables

START_COUNTER/propagation_speed - 2 rows (straight, nose)

A Propagation speed correction factors
Aerr
B
Berr


START_COUNTER/attenuation_factor

A Attenuation correction factors
Aerr
B
Berr
C
Cerr
D
Derr
F
Ferr

START_COUNTER/timewalk_corrections - to be decided

START_COUNTER/start_parms

START_SIGMA 0.3 Start counter timing resolution 300ps
START_PHOTONS_PERMEV 200. Start counter number of photons per MeV
START_ATTEN_LENGTH 150. attenuation length in cm
START_C_EFFECTIVE 15. effective speed of light in cm/ns
START_TWO_HIT_RESOL 25. time window for two hit resolution in ns
START_MAX_HITS 100 maximum number of hits per readout channel
START_THRESH_MEV 0.150 threshold in MeV
START_LIGHT_GUIDE 140. light guid length in cm
START_ANGLE_COR 1.17  ?
START_BENT_REGION 50.  ?