Difference between revisions of "CCDB Tables CDC"

From GlueXWiki
Jump to: navigation, search
(Tables)
m (Tables)
Line 62: Line 62:
 
Note - maybe this should be a JANA parameter?
 
Note - maybe this should be a JANA parameter?
  
'''CDC/MC/drift\_func\_parms'''
+
'''CDC/MC/drift_func_parms'''
 
{|class="wikitable"
 
{|class="wikitable"
 
| style="width:130px;" | CDC_DRIFT_A
 
| style="width:130px;" | CDC_DRIFT_A
Line 89: Line 89:
 
|}
 
|}
  
'''CDC/fit\_parms'''
+
'''CDC/fit_parms'''
 
{|class="wikitable"
 
{|class="wikitable"
 
| style="width:130px;" | CDC_VARIANCE_A
 
| style="width:130px;" | CDC_VARIANCE_A
Line 99: Line 99:
 
| CDC_VARIANCE_C
 
| CDC_VARIANCE_C
 
|
 
|
 +
|}
 +
 +
'''CDC/cdc_parms'''
 +
{|class="wikitable"
 +
| style="width:70px;" | CDC_TDRIFT_SIGMA
 +
| style="width:90px;" | 2.8181818181818e-9
 +
| style="width:400px;" | The error on the drift time in the CDC, used to gaussianly smear actual CDC hits.
 +
|-
 +
| CDC_TIME_WINDOW
 +
| 1000.0E-9
 +
| The time window for which CDC hits are accumulated (in sec), used for background determination
 +
|-
 +
| CDC_PEDESTAL_SIGMA
 +
| 0.00000006
 +
| The error in the energy deposition measurement in the CDC due to pedestal noise
 +
|-
 +
| CDC_DRIFT_SPEED
 +
| 0.0055
 +
| CDC drift speed (unit?)
 +
|-
 +
| CDC_TWO_HIT_RESOL
 +
| 25.
 +
| time window for two hit resolution (in ns)
 +
|-
 +
| CDC_MAX_HITS
 +
| 100
 +
| number of hit per readout channel
 +
|-
 +
| CDC_THRESH_KEV
 +
| 1.
 +
| threshold applied (in KeV)
 +
|-
 +
| CDC_STRAW_RADIUS
 +
| 0.8
 +
| straw radius (in cm)
 
|}
 
|}
  

Revision as of 17:02, 26 March 2014

Variations

These are interesting variations related to the CDC:

  • CDC_8mm_0T, CDC_9mm_0T, CDC_10mm_0T - versions of time-distance tables for different sized straws, no magnetic field. only 25 tables generated, with mixtures of 47/53 to 53/47 of Ar/CO2, in 0.25% increments.

Tables

CDC/timing_offsets

1-3522 timing offset, t0 (ns)

CDC/wire_gains

1-3522 gain correction factor

CDC/wire_alignment (3522 rows)

dxu upstream wire end displacement - X
dyu upstream wire end displacement - Y
dxd downstream wire end displacement - X
dyd downstream wire end displacement - Y

CDC/alignment

CDC_ALIGN_UPSTREAM_DZ upstream endplate z displacement
CDC_ALIGN_DOWNSTREAM_DZ downstream endplate z displacement
CDC_SAG_RADIUS

CDC/cdc_gas_tables, 41 rows

1-100 time-to-distance lookup tables

CDC/drift_parms

CDC_DRIFT_FUNCTION index for which row of CDC/cdc_gas_drift should be used

Note - maybe this should be a JANA parameter?

CDC/MC/drift_func_parms

CDC_DRIFT_A Transverse drift function parameters
CDC_DRIFT_B
CDC_DRIFT_C
CDC_DRIFT_D
CDC_DRIFT_A_L Longitudinal drift function parameters
CDC_DRIFT_B_L
CDC_DRIFT_C_L
CDC_DRIFT_D_L

CDC/fit_parms

CDC_VARIANCE_A Kalman filter parameters
CDC_VARIANCE_B
CDC_VARIANCE_C

CDC/cdc_parms

CDC_TDRIFT_SIGMA 2.8181818181818e-9 The error on the drift time in the CDC, used to gaussianly smear actual CDC hits.
CDC_TIME_WINDOW 1000.0E-9 The time window for which CDC hits are accumulated (in sec), used for background determination
CDC_PEDESTAL_SIGMA 0.00000006 The error in the energy deposition measurement in the CDC due to pedestal noise
CDC_DRIFT_SPEED 0.0055 CDC drift speed (unit?)
CDC_TWO_HIT_RESOL 25. time window for two hit resolution (in ns)
CDC_MAX_HITS 100 number of hit per readout channel
CDC_THRESH_KEV 1. threshold applied (in KeV)
CDC_STRAW_RADIUS 0.8 straw radius (in cm)

Deprecated

The following tables should not be used anymore:

  • CDC/cdc_drift - parameterized time-to-distance function