Difference between revisions of "CCDB Tables CDC"

From GlueXWiki
Jump to: navigation, search
m (Variations)
(Tables)
Line 9: Line 9:
 
==Tables==
 
==Tables==
  
 +
'''CDC/timing_offsets'''
 +
{|class="wikitable"
 +
| style="width:10%;" | 1-3522
 +
| style="width:40%;" | timing offset, t0 (ns)
 +
|}
  
 +
'''CDC/wire_gains'''
 +
{|class="wikitable"
 +
| style="width:10%;" | 1-3522
 +
| style="width:40%;" | gain correction factor
 +
|}
 +
 +
'''CDC/wire_alignment'''  (3522 rows)
 +
{|class="wikitable"
 +
| style="width:10%;" | dxu
 +
| style="width:40%;" | upstream wire end displacement - X
 +
|-
 +
| dyu
 +
| upstream wire end displacement - Y
 +
|-
 +
| dxd
 +
| downstream wire end displacement - X
 +
|-
 +
| dyd
 +
| downstream wire end displacement - Y
 +
|}
 +
 +
'''CDC/alignment'''
 +
{|class="wikitable"
 +
| style="width:10%;" | CDC_ALIGN_UPSTREAM_DZ
 +
| style="width:40%;" | upstream endplate z displacement
 +
|-
 +
| CDC_ALIGN_DOWNSTREAM_DZ
 +
| downstream endplate z displacement
 +
|-
 +
| CDC_SAG_RADIUS
 +
|
 +
|}
 +
 +
'''CDC/cdc_gas_tables''', 41 rows
 +
{|class="wikitable"
 +
| style="width:10%;" | 1-100
 +
| style="width:40%;" | time-to-distance lookup tables
 +
|}
 +
 +
'''CDC/drift_parms'''
 +
{|class="wikitable"
 +
| style="width:10%;" | CDC_DRIFT_FUNCTION
 +
| style="width:40%;" | index for which row of CDC/cdc_gas_drift should be used 
 +
|}
 +
 +
Note - maybe this should be a JANA parameter?
 +
 +
'''CDC/MC/drift\_func\_parms'''
 +
{|class="wikitable"
 +
| style="width:10%;" | CDC_DRIFT_A
 +
| style="width:40%;" | Transverse drift function parameters
 +
|-
 +
| CDC_DRIFT_B
 +
|
 +
|-
 +
| CDC_DRIFT_C
 +
|
 +
|-
 +
| CDC_DRIFT_D
 +
|
 +
|-
 +
| CDC_DRIFT_A_L
 +
| Longitudinal drift function parameters
 +
|-
 +
| CDC_DRIFT_B_L
 +
|
 +
|-
 +
| CDC_DRIFT_C_L
 +
|
 +
|-
 +
| CDC_DRIFT_D_L
 +
|
 +
|}
 +
 +
'''CDC/fit\_parms'''
 +
{|class="wikitable"
 +
| style="width:10%;" | CDC_VARIANCE_A
 +
| style="width:40%;" | Kalman filter parameters
 +
|-
 +
| CDC_VARIANCE_B
 +
|
 +
|-
 +
| CDC_VARIANCE_C
 +
|
 +
|}
  
 
==Deprecated==
 
==Deprecated==
  
 
The following tables should not be used anymore:
 
The following tables should not be used anymore:

Revision as of 18:38, 25 March 2014

Variations

These are interesting variations related to the CDC:

  • CDC_8mm_0T, CDC_9mm_0T, CDC_10mm_0T - versions of time-distance tables for different sized straws, no magnetic field

Tables

CDC/timing_offsets

1-3522 timing offset, t0 (ns)

CDC/wire_gains

1-3522 gain correction factor

CDC/wire_alignment (3522 rows)

dxu upstream wire end displacement - X
dyu upstream wire end displacement - Y
dxd downstream wire end displacement - X
dyd downstream wire end displacement - Y

CDC/alignment

CDC_ALIGN_UPSTREAM_DZ upstream endplate z displacement
CDC_ALIGN_DOWNSTREAM_DZ downstream endplate z displacement
CDC_SAG_RADIUS

CDC/cdc_gas_tables, 41 rows

1-100 time-to-distance lookup tables

CDC/drift_parms

CDC_DRIFT_FUNCTION index for which row of CDC/cdc_gas_drift should be used

Note - maybe this should be a JANA parameter?

CDC/MC/drift\_func\_parms

CDC_DRIFT_A Transverse drift function parameters
CDC_DRIFT_B
CDC_DRIFT_C
CDC_DRIFT_D
CDC_DRIFT_A_L Longitudinal drift function parameters
CDC_DRIFT_B_L
CDC_DRIFT_C_L
CDC_DRIFT_D_L

CDC/fit\_parms

CDC_VARIANCE_A Kalman filter parameters
CDC_VARIANCE_B
CDC_VARIANCE_C

Deprecated