Blake CAP08 Abstract

From GlueXWiki
Revision as of 13:04, 3 July 2008 by Zisis (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

A photon beam test of the 4~m long prototype lead/scintillating fibre module for the \GX\ electromagnetic barrel calorimeter was carried out in Hall B at the Thomas Jefferson National Accelerator Facility with the objective of measuring the energy and timing resolutions of the module as well as the number of photoelectrons generated. Data were collected over an energy range of 150 to 650 MeV at multiple positions and angles along the module. Details of the analysis at the centre of and perpendicular to the module are shown herein; the results are $\sigma_{\Delta T/2} = 70/\sqrt{E}$ ps, $\sigma_{E}/E = 5.5\%/\sqrt{E}$ and 770 photoelectrons for 1 GeV at each end of the module.