=== Calibration === | === Calibration === | ||
+ | |||
+ | # Timing calibration for FCAL, CCAL (ST, TOF, BCAL, tagging detectors) | ||
+ | |||
+ | # Recalibrate CCAL (non-linearity corrections) -- Drew | ||
+ | *: Adjust tagger energy scale -- Sasha | ||
+ | |||
+ | # FCAL calibration | ||
+ | *: Was the decision to use GlueX official reconstruction (or an Island algorithm). | ||
+ | *: Do we need |
Revision as of 11:33, 11 October 2019
Event generators (should be in the PrimEx analysis directory)
- Signal Primakoff
- Coherent / incoherent
- Hardonic background (generate MC samples of contributing decays)
- Compton with rad corrections
- Currently have simple 'Klein Nishina' generator with 1/E energy-dependent spectrum
- Need to implement realistic shape of photon spectrum (efficiency)
- Double Compton Generator (Pavel)
- Need to generate MC samples according to realistic run conditions (samples for each run)
Calibration
- Timing calibration for FCAL, CCAL (ST, TOF, BCAL, tagging detectors)
- Recalibrate CCAL (non-linearity corrections) -- Drew
- Adjust tagger energy scale -- Sasha
- FCAL calibration
- Was the decision to use GlueX official reconstruction (or an Island algorithm).
- Do we need