Fiber test stand

From GlueXWiki
Revision as of 09:19, 29 May 2008 by Wolin (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

From Beni:


1) data acquisition

  • 1 crate (VME, Camac, or Fastbus)
  • 1 crate controller
  • 1-2 ADC charge sensing ADC's
  • 1 TDC (optional)
  • 1 Trigger Interface
  • 1 Computer/software to communicate with crate controller


2) NIM electronics

  • 1 crate
  • 2 Discriminators
  • 2 Coincidence units
  • 1 Gate Generator or Coincidence unit that can be VETOed
  • 1 CFD (optional)


3) misc. Electronics

  • Oscilloscope
  • Digital multimeter with RS232 interface or other electronic readout means
  • cables with LEMO connectors and BNC connectors (for delays)
  • some BNC-lemo adapters and other BNC and LEMO equipment