CDC threshold scan procedure
From GlueXWiki
Ideally, with cosmics...
First we need a baseline calibration to set the DAC offsets to put the pedestals at 100.
(Then Beni makes the configuration files for the following runs, using the new DAC offsets).
We need a short run with these values for the threshold H:
- 80
- 85
- 90
- 100
1 evio file in short mode is sufficient for each setting.
TH=60 and TL=10 as usual.