CCDB Tables Start Counter
From GlueXWiki
Contents
Variations
No interesting variations at the moment.
Proposed Tables
START_COUNTER/propagation_speed - 2 rows (straight, nose)
A | Propagation speed correction factors |
Aerr | |
B | |
Berr |
START_COUNTER/attenuation_factor
A | Attenuation correction factors |
Aerr | |
B | |
Berr | |
C | |
Cerr | |
D | |
Derr | |
F | |
Ferr |
START_COUNTER/timewalk_corrections - to be decided
START_COUNTER/start_parms
START_SIGMA | 0.3 | Start counter timing resolution 300ps |
START_PHOTONS_PERMEV | 200. | Start counter number of photons per MeV |
START_ATTEN_LENGTH | 150. | attenuation length in cm |
START_C_EFFECTIVE | 15. | effective speed of light in cm/ns |
START_TWO_HIT_RESOL | 25. | time window for two hit resolution in ns |
START_MAX_HITS | 100 | maximum number of hits per readout channel |
START_THRESH_MEV | 0.150 | threshold in MeV |
START_LIGHT_GUIDE | 140. | light guid length in cm |
START_ANGLE_COR | 1.17 | ? |
START_BENT_REGION | 50. | ? |