CDC signal integration

From GlueXWiki
Revision as of 15:38, 19 June 2012 by Nsjarvis (Talk | contribs)

Jump to: navigation, search


50/50 gas, 2100V

        • Caveat: data were with preamp underpowered, 2.65V on preamp card ****



Try to calculate dE/dx

integration from low threshold crossing for next 700ns / track length
No tilt
Tilted at 45 degrees

This does not scale very nicely with track length.


Track length is calculated in the plane parallel to the endplates (no z information) so I scaled it by the tilt of the prototype for the 45 degree data, the upper cosmic trigger scintillator is high up enough that the cosmics are ~ vertical

height of first maximum in signal amplitude / track length
No tilt
Tilted at 45 degrees


signal integrated from low threshold crossing to position of first maximum in signal amplitude / track length
No tilt
Tilted at 45 degrees


Look at time over threshold...

Peak duration is # samples after the lower threshold crossing until the ADC value decreases by 2sigma over 2 samples, this is a measure of time over threshold in units of 8ns


Peak duration
No tilt
Tilted at 45 degrees


Peak duration / track length
No tilt
Tilted at 45 degrees


Peak length vs first maximum in signal amplitude
No tilt
Tilted at 45 degrees