Comparison of radiation damage between FLUKA and Geant
From GlueXWiki
- Photon energy spectrum used in the simulations (photon flux corresponds to high-luminosity run)
- Silicon damage function used by FLUKA
- Particle spectra through the SiPM
- Particle fluences around barrel calorimeter in terms of 1-MeV equivalent neutrons in Si
- Total 1-MeV (Si) neutron equivalent fluence in Si PM plane
- Particle fluences in Hall D in terms of 1-MeV equivalent neutrons in Si
- Particles per cm^2 per second in terms of 1-MeV neutron equivalent in Si estimated with FLUKA simulation (Photon beam power at target = .704 W)
Total | Neutrons | Protons | Pions | Electrons | Positrons |
22.95 ± 0.18 | 18.07 ± 0.13 | 1.72 ± 0.02 | 1.81 ± 0.01 | 1.01 ± 0.20 | 0.19 ± 0.03 |
- Neutron flux in terms of 1-MeV equivalent neutrons in Si estimated with Geant simulation: 30.5 cm^-2 sec^-1.
- FLUKA geometry and input files: http://www.jlab.org/~georgek/halld/