Comparison of radiation damage between FLUKA and Geant
From GlueXWiki
- Photon energy spectrum used in the simulations (photon flux corresponds to high-luminosity run)
- Silicon damage function used by FLUKA
- Particle spectra through the SiPM
- Particle fluences around barrel calorimeter in terms of 1-MeV equivalent neutrons in Si
- Particle fluences in Hall D in terms of 1-MeV equivalent neutrons in Si
- Particles per cm^2 per second in terms of 1-MeV neutron equivalent in Si estimated with FLUKA simulation (Photon beam power at target = .704 W)
Total | Neutrons | Protons | Pions | Electrons | Positrons |
24.7 ± 1.1 | 19.5 ± 0.9 | 1.8 ± 0.1 | 2.0 ± 0.1 | 0.9 ± 0.1 | 0.3 ± 0.1 |
- Neutron flux in terms of 1-MeV equivalent neutrons in Si estimated with Geant simulation: 30.5 cm^-2 sec^-1.
- FLUKA geometry and input files