Boards in the crate
Board | Slot | Serial |
---|---|---|
CPU (halldtrg5) | 1 | |
TI (Old) | 2 | |
FADC250 | 5 | B21595_06R |
SDC | 9 | |
LE discriminator | 14 | C_15 |
F1TDC | 16 |
Front pannel connections
From | To |
---|---|
External trigger | TI input, IN1 |
L1 Accept ( 3rd from the bottom ) | SDC TRG |
L1 Accept ( 4 th from the bottom ) | F1TDC TRG |
TI Out0 | F1TDC SYNC |
Setting up the setup
- Connect keybord and monitor (if needed) to the Intel ROC.
- Connect Ethernet cable to the upper ROC LAN connector.
- Change ROC IP address (you will see the MAC address when you start booting the controller)
- Login under halld
Directories
Most DAQ files (CODA), the Run Control and other applications have been installed localy on the ROC flash disc. You will need to mount the remote data disc to store data files.
Below is a description of some directories.
- The home directory is /home/halld
- /home/halld/micro/rol contains the F1TDC configuration file and the link to the DAC readout list (see descriptions below)
- /home/halld/micro/coda contains Run Control data base
- /home/halld/data is a directory for the DAQ data storage. The external drive has to be mounted to here
- /home/halld/micro/coda_micro_setup is a script with configuration variables
- you have to edit this file ad change some variables if needed
- source coda_micro_setup to set variables up
- Coda and Run Control files are installed at /usr/local/coda
How to run DAQ
Change electronics boards initialization parameters