Difference between revisions of "CDC prototype drift times"
From GlueXWiki
Line 52: | Line 52: | ||
|width="300pt"| | |width="300pt"| | ||
[[Image:driftfit17_thr10_225.png|thumb|300px|fitted drift distance for straw 17 for all tracks and same-column tracks, threshold 10sigma ]] | [[Image:driftfit17_thr10_225.png|thumb|300px|fitted drift distance for straw 17 for all tracks and same-column tracks, threshold 10sigma ]] | ||
+ | |} | ||
+ | |||
+ | Spikes found in trigger signal | ||
+ | {| border="0" cellpadding="2" | ||
+ | |width="300pt"| | ||
+ | [[Image:trigger_spikes.png|thumb|300px|trigger times ]] | ||
|} | |} |
Revision as of 10:02, 28 November 2011
CDC prototype cosmics data
- 50/50 mixed Ar, CO2
- Recalibrated MFCs
- Outer plenum added to CDC prototype to prevent leaks
- New pre-production HVB
- 2100V
- Modified preamp4 (terminating resistors removed)
- Prototype tilted at 30o to enclosing scintillators (scints trigger the daq)
- New timing setup (recording coinc logic signal)
Purple histogram is drift time in tracks through each straw; gray selects tracks through all 3 straws in same column, hit threshold is 5sigma over pedestal
hit threshold is 10sigma over pedestal
Below: Purple:all tracks through straw, grey: track angle 5° or more to vertical, light blue: track angle less than 5° to vertical. Hit threshold 5 sigma over pedestal
Same again just for straw 17
Fitted drift distance for straw 17, for all tracks, and tracks through all 3 straws in the same vertical column, hit threshold 5sigma (left) and 10sigma (right)
Same again with more bins
Spikes found in trigger signal