Difference between revisions of "Requirements for Controls Systems from various detector components"
From GlueXWiki
(→Start Counter) |
(→FDC) |
||
Line 21: | Line 21: | ||
# Readout and monitoring of of temperature sensors : | # Readout and monitoring of of temperature sensors : | ||
#* Estimated ~10 input channels (from Lubomir and Beni) | #* Estimated ~10 input channels (from Lubomir and Beni) | ||
+ | # Cooling system control | ||
+ | #* Valves, temperatures ???? | ||
# Control of HV channels CAEN A1535 | # Control of HV channels CAEN A1535 | ||
#* Estimated 130 channels (Doc. 967-v6) | #* Estimated 130 channels (Doc. 967-v6) | ||
#Control of LV on preamp cards (MPV 8008 or CAEN A1518) | #Control of LV on preamp cards (MPV 8008 or CAEN A1518) | ||
#* Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4) | #* Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4) | ||
− | |||
− | |||
== CDC == | == CDC == |
Revision as of 13:20, 8 December 2010
BCAL
- Readout and monitoring of temperature sensors
- Estimated ~10 input channels (from Elton)
- Control of 70V Bias LV channels on SiPMs
- Estimated 144 channels ?????
- Control of 5V LV on amplifiers
- Estimated 96 channels ??????
FCAL
- Control of HV on CW PMTs (IU is taking care of most of this)
- Estimated 2800 channels (from Matt)
- Control and monitor thresholds
- Estimated 2800 channels (from Matt)
FDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Cooling system control
- Valves, temperatures ????
- Control of HV channels CAEN A1535
- Estimated 130 channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4)
CDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 24 negative and 24 positive channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 16 channels (WIENER) or 18 channels (CAEN) (Doc. 966-v4)
Tagger
- Control of HV channels
- Estimated 310 channels (Fernando's table)
- Motion control
- 3 motors to control the microscope
Beamline
- Goni control
- control 3 axis of motion of to position the crystal and it's orientation
- Harps
- 2 harps, one before the radiator, another one before the beam dump
- control 2 axis of collimator motion
- control the position of the total absorption counter
- Sweeping Magnets
- Control 1 PS for the big sweeping magnets
- 1 Gaussmeter readout to measure the field in the sweeping magnet
Pair Spectrometer
- Control pair spectrometer magnet
- Serial port communication to the power supply
- 1 Gauss-meter to B-field measurement
- HV/LV control
- Approximately 20 channels, too early to decide
- Positioning of the converter
- 1 axis motion
Start Counter
- HV for start counter
- 40 HV channel control
TOF
- HV for TOF counter
- Control 168 channels of HV for TOF