Difference between revisions of "Requirements for Controls Systems from various detector components"
From GlueXWiki
(→BCAL) |
|||
Line 35: | Line 35: | ||
# Control of LV on preamp cards (MPV 8008 or CAEN A1518) | # Control of LV on preamp cards (MPV 8008 or CAEN A1518) | ||
#* Estimated 16 channels (WIENER) or 18 channels (CAEN) (Doc. 966-v4) | #* Estimated 16 channels (WIENER) or 18 channels (CAEN) (Doc. 966-v4) | ||
+ | |||
+ | |||
+ | |||
+ | == Tagger == | ||
+ | |||
+ | # Control of HV channels | ||
+ | #* Estimated 310 channels (Fernando's table) | ||
+ | # Motion control | ||
+ | #* 3 motors to control the microscope | ||
+ | |||
+ | |||
+ | == Beamline == | ||
+ | # Goni control | ||
+ | #* control 3 axis of motion of to position the crystal and it's orientation | ||
+ | # Harps | ||
+ | #* 2 harps, one before the radiator, another one before the beam dump | ||
+ | #* control 2 axis of collimator motion | ||
+ | #* control 1 motor for converter/photon harp | ||
+ | #* control the position of the total absorption counter |
Revision as of 11:53, 8 December 2010
BCAL
- Readout and monitoring of temperature sensors
- Estimated ~10 input channels (from Elton)
- Control of 70V Bias LV channels on SiPMs
- Estimated 144 channels ?????
- Control of 5V LV on amplifiers
- Estimated 96 channels ??????
FCAL
- Control of HV on CW PMTs (IU is taking care of most of this)
- Estimated 2800 channels (from Matt)
- Control and monitor thresholds
- Estimated 2800 channels (from Matt)
FDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 130 channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4)
CDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 24 negative and 24 positive channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 16 channels (WIENER) or 18 channels (CAEN) (Doc. 966-v4)
Tagger
- Control of HV channels
- Estimated 310 channels (Fernando's table)
- Motion control
- 3 motors to control the microscope
Beamline
- Goni control
- control 3 axis of motion of to position the crystal and it's orientation
- Harps
- 2 harps, one before the radiator, another one before the beam dump
- control 2 axis of collimator motion
- control 1 motor for converter/photon harp
- control the position of the total absorption counter