BCAL
- Readout and monitoring of temperature sensors
- Estimated ~10 input channels (from Elton)
- Control of 70V Bias LV channels on SiPMs
- Estimated 144 channels ?????
- Control of 5V LV on amplifiers
- Estimated 96 channels ??????
FCAL
- Control of HV on CW PMTs (IU is taking care of most of this)
- Estimated 2800 channels (from Matt)
- Control and monitor thresholds
- Estimated 2800 channels (from Matt)
FDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 130 channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4)
CDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 24 negative and 24 positive channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)