Difference between revisions of "SiPM Radiation Hardness Test"
From GlueXWiki
m (→Device List) |
(→Device List) |
||
Line 12: | Line 12: | ||
* Oscilliscope: TDS3034: dosci.jlab.org (129.57.192.77) | * Oscilliscope: TDS3034: dosci.jlab.org (129.57.192.77) | ||
* Power Outlet: APC Outlet Control: hlauser:hlauser@hareboot12.jlab.org (129.57.192.76) | * Power Outlet: APC Outlet Control: hlauser:hlauser@hareboot12.jlab.org (129.57.192.76) | ||
− | ** Outlet 1: | + | ** Outlet 1: USB-Serial and USB over IP |
− | ** Outlet 2: | + | ** Outlet 2: Temperature Box |
− | ** Outlet 3: | + | ** Outlet 3: Oscilliscope |
− | ** Outlet 4: | + | ** Outlet 4: GPIB over IP |
− | ** Outlet 5: | + | ** Outlet 5: Power Supply for Hamamatsu Unit |
− | ** Outlet 6: | + | ** Outlet 6: Power Supply for SensL Unit |
− | ** Outlet 7: | + | ** Outlet 7: Picoamp Meter |
− | ** Outlet 8: | + | ** Outlet 8: Pulse Generator |
− | * USB to Serial HUB: ComHUB | + | * USB to Serial HUB: ComHUB |
+ | ** Serial 1: Power Supply for Hamamatsu Unit | ||
+ | ** Serial 2: Power Supply for SensL Unit | ||
+ | ** Serial 3: Oscilliscope | ||
+ | ** Serial 4: Temperature Box | ||
* Picoamp Meter x2: Keithley-485 (GPIB) | * Picoamp Meter x2: Keithley-485 (GPIB) | ||
+ | ** GPIB Address: 1 (Hamamatsu); 2 (SensL) | ||
* Pulse Generator: HP-8116A (GPIB) | * Pulse Generator: HP-8116A (GPIB) | ||
+ | ** GPIB Address: 4 | ||
* Power Supply x2: B&K-1787B (RS232) | * Power Supply x2: B&K-1787B (RS232) | ||
* Temperature Meter: CN77544 (RS232) | * Temperature Meter: CN77544 (RS232) |
Revision as of 15:26, 16 March 2010
SiPM Radiation Hardness Test in Hall A
Test Plan
System Diagram
Device List
- Control Computer: transversity.jlab.org: (129.57.164.28)
- GPIB over IP: GPIB-ENET/100: agpib.jlab.org (129.57.192.73)
- USB over IP: AnywhereUSB/5: ausb.jlab.org (129.57.192.75)
- Oscilliscope: TDS3034: dosci.jlab.org (129.57.192.77)
- Power Outlet: APC Outlet Control: hlauser:hlauser@hareboot12.jlab.org (129.57.192.76)
- Outlet 1: USB-Serial and USB over IP
- Outlet 2: Temperature Box
- Outlet 3: Oscilliscope
- Outlet 4: GPIB over IP
- Outlet 5: Power Supply for Hamamatsu Unit
- Outlet 6: Power Supply for SensL Unit
- Outlet 7: Picoamp Meter
- Outlet 8: Pulse Generator
- USB to Serial HUB: ComHUB
- Serial 1: Power Supply for Hamamatsu Unit
- Serial 2: Power Supply for SensL Unit
- Serial 3: Oscilliscope
- Serial 4: Temperature Box
- Picoamp Meter x2: Keithley-485 (GPIB)
- GPIB Address: 1 (Hamamatsu); 2 (SensL)
- Pulse Generator: HP-8116A (GPIB)
- GPIB Address: 4
- Power Supply x2: B&K-1787B (RS232)
- Temperature Meter: CN77544 (RS232)