Difference between revisions of "Run Planning Meeting Notes, July 07 - July 14, 2022"
From GlueXWiki
(→Past 24 hours) |
|||
Line 8: | Line 8: | ||
[https://docs.google.com/spreadsheets/d/1sdluzy7p5vnlhw9AWJHBrYbXKTBet45o4den4zWX9dc/edit#gid=1855021251 Spreadsheet with list of runs] | [https://docs.google.com/spreadsheets/d/1sdluzy7p5vnlhw9AWJHBrYbXKTBet45o4den4zWX9dc/edit#gid=1855021251 Spreadsheet with list of runs] | ||
+ | |||
+ | = Thursday July 8 = | ||
+ | |||
+ | === Past 24 hours === | ||
+ | |||
+ | * harp scans were done during short beam on period during day-time, some distributions show 1/100 peak/shoulders ratio others 1/10,000 [https://logbooks.jlab.org/entry/4012157] [https://logbooks.jlab.org/entry/4012169] | ||
+ | * Dominion Power's work required a voltage reduction so we had tagger, PS and sweep magnets off for a couple of hours | ||
+ | * collected cosmics and LED runs during daytime, and production on lead (about 8 hrs) during night time | ||
+ | |||
+ | === Shift reports === | ||
+ | * [https://logbooks.jlab.org/entry/4012170 day shift summary] | ||
+ | * [https://logbooks.jlab.org/entry/4012365 swing shift summary] | ||
+ | * [https://logbooks.jlab.org/entry/4012468 owl shift summary] | ||
+ | * [https://logbooks.jlab.org/entry/4012564 early riser shift summary] | ||
+ | |||
+ | === Reports === | ||
+ | * Sasha checked FCAL trigger rate without masking inner layers. Preliminary result for the rate was 14kHz [https://logbooks.jlab.org/entry/4012436] | ||
+ | |||
+ | === Issues === | ||
+ | * Problems with running at 60nA on AMO, radiator thickness was reduced to 3*10^-4 this night, | ||
+ | as 4.5*10^-4 was causing IOC trips [https://logbooks.jlab.org/entry/4012504] | ||
+ | * DIRC major alarm has been acknowledged [https://logbooks.jlab.org/entry/4012485], Mark may need to investigate this issue more | ||
+ | * Dave has noticed we have a higher radiation level values now, about factor of 1.5 [https://logbooks.jlab.org/entry/4012423], [https://logbooks.jlab.org/entry/4012426] | ||
+ | * Hydra alarm on fa125_itrig [https://logbooks.jlab.org/entry/4012288] | ||
+ | * daq livetime is uneven from time to time [https://logbooks.jlab.org/entry/4012631] | ||
+ | |||
+ | === Plans === | ||
+ | * Continue production on lead | ||
+ | * Unmasking FCAL modules | ||
+ | |||
= Wednesday July 7 = | = Wednesday July 7 = |
Revision as of 08:28, 8 July 2022
Back to Run Coordination Meetings:Summer2022
Meeting are via ZoomGov: connect (Meeting ID: 160 199 0060 / Passcode 8394)
Hall D counting room white board
Contents
Thursday July 8
Past 24 hours
- harp scans were done during short beam on period during day-time, some distributions show 1/100 peak/shoulders ratio others 1/10,000 [1] [2]
- Dominion Power's work required a voltage reduction so we had tagger, PS and sweep magnets off for a couple of hours
- collected cosmics and LED runs during daytime, and production on lead (about 8 hrs) during night time
Shift reports
Reports
- Sasha checked FCAL trigger rate without masking inner layers. Preliminary result for the rate was 14kHz [3]
Issues
- Problems with running at 60nA on AMO, radiator thickness was reduced to 3*10^-4 this night,
as 4.5*10^-4 was causing IOC trips [4]
- DIRC major alarm has been acknowledged [5], Mark may need to investigate this issue more
- Dave has noticed we have a higher radiation level values now, about factor of 1.5 [6], [7]
- Hydra alarm on fa125_itrig [8]
- daq livetime is uneven from time to time [9]
Plans
- Continue production on lead
- Unmasking FCAL modules
Wednesday July 7
Past 24 hours
- Malte and Mark worked on FCAL bases replacement [10]
- One of the RF crates had been disconnected, Beni fixed it [11]
- Bobby and others worked in the tagger hall during the day. At 3:30 pm Bobby noticed that the IOC for the NMR was not responding properly. MCC rebooted the IOC crate. Afterward, it was still locked on zero and there was still a Comm Status error [12]
- Beni found that the solenoid controls hung, and restarted the ramping, which was helpful.
- Had minor issues with DAQ at 7.00 pm: ROCFDC11 error: timeout error on FA125, every 3 seconds. (fADC125 in fdc11 slot 3 was replaced during daytime [13]) Sergei worked out the DAQ issue at 7.50 pm
- Established operating field of the solenoid at 8:30 pm.
- harp scans are ongoing now
Shift reports
Reports
- Sergey and Lubomir worked in the Hall this night from 10 pm to 11:30 pm [14]
- Hovanes reported his study of the coherent peak position drifts observed on the 4th of July [15]
- Still have 60Hz structure [16]. The situation is improved according to MCC experts.
- CDC HV and TAGM alarms are more frequent now
- CDC gas flow increased [17]
Issues
Plans
- Continue production on lead
- Unmasking FCAL central modules from the trigger needs to be done unless it increases rate too high