Line 216: |
Line 216: |
| |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad10mm_res34.png|thumb|x250px|Resolution ch34, >80% hits on track, 10mm Garfield r]] | | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad10mm_res34.png|thumb|x250px|Resolution ch34, >80% hits on track, 10mm Garfield r]] |
| |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad10mm_res34_5mm.png|thumb|x250px|Resolution ch34, drift radius > 5mm, >80% hits on track, 10mm Garfield r]] | | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad10mm_res34_5mm.png|thumb|x250px|Resolution ch34, drift radius > 5mm, >80% hits on track, 10mm Garfield r]] |
| + | |} |
| + | |
| + | {| border="0" cellpadding="2" |
| + | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad8mm_resx34.png|thumb|x250px|Resolution vs drift radius ch34, >80% hits on track, 8mm Garfield r]] |
| + | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad8mm_res34.png|thumb|x250px|Resolution ch34, >80% hits on track, 8mm Garfield r]] |
| + | |[[Image:cdc_run_32292_5149_tz16_tfix1000_rad8mm_res34_5mm.png|thumb|x250px|Resolution ch34, drift radius > 5mm, >80% hits on track, 8mm Garfield r]] |
| |} | | |} |
Revision as of 11:02, 3 July 2013
Boards E8, E9, E10, max amp histo, threshold 5
|
Boards E8, E9, E10, drift time, threshold 5
|
Boards E8, E9, E10, max amp histo, threshold 6#sigma
|
Boards E8, E9, E10, drift time, threshold 6
|
Boards E8, E9, E10, drift time fit, threshold 6
|
Drift time fit
Estimate of t0 is 850.09 and tmax is 1464.19, difference is 614.10
Straight-line intercept is 834.51, to match histogram fit t0, use tz_add 15.58
Drift time vs channel number, threshold 5#sigma
|
Drift time vs channel number, threshold 5#sigma and amplitude>180
|
Number of hits which were not on the fitted track
|
Off-track hits vs total hits
|
Event 23, 4 hits off-track
|
Event 253, 48 hits off-track
|
Event 1037, 21 hits off-track
|
Resolutions using tz=16 and Garfield for 2100V, 51Ar, 49CO2
Resolution, ALL CHANNELS, violet=total hits<24, dk blue: 5 or less hits off track
|
Resolution vs channel number
|
Resolution, E9 board channels, <5 hits off track
|
Resolution vs driftradius
|
Different scint orientations
Boards E8, E9, E10, big scintillators, across CDC, upstream end
|
Boards E8, E9, E10, big scintillators, across CDC, downstream end
|
Boards E8, E9, E10, big scintillators, along CDC
|
Boards E8, E9, E10, big scintillators, along CDC, fit to thr5 data
|
Drift time fits, hit threshold 5#sigma
big scintillators, across CDC, upstream end
|
big scintillators, across CDC, downstream end
|
big scintillators, along CDC
|
Hit threshold 6#sigma
big scintillators, across CDC, upstream end
|
big scintillators, across CDC, downstream end
|
big scintillators, along CDC
|
Hit threshold 6#sigma
big scintillators, along CDC, HV grounded to endplate (not HVBs)
|
big scintillators, along CDC, added shielding to + HV cables
|
drift time for each channel
|
|
drift time for channels 34, 35
|
max amplitude for channels 34, 35
|
pedestal width for channels 34, 35
|
max amplitude vs drift time for channel 34
|
max amplitude vs drift time for channel 35
|
drift times with ch 34 nonzero
|
drift times with ch 34 drift time > 1500
|
tracks with ch 34 drift time > 800
|
tracks with ch 34 drift time > 1550
|
close-up of tracks with ch 34 drift time > 1550
|
Drift times (ns) from Garfield for 2110V, 50/50 gas mix, different tube radii
-dist(mm)
|
8mm (2kV)
|
9mm (2.1kV)
|
10mm (2.1kV)
|
6mm |
381 |
387 |
394
|
7mm |
527 |
535 |
544
|
7.5mm |
608 |
618 |
628
|
7.8mm |
660 |
670 |
681
|
8mm |
|
706 |
717
|
8.5mm |
|
800 |
813
|
9mm |
|
|
914
|
9.5mm |
|
|
1020
|
Tracks for other straws with drift times>1550ns, searched 50k events for straws 36 and 38, 5k for the rest
|
|
|
|
|
|
|
close-up of tracks with ch 39 drift time > 1550
|
|
close-up of tracks with ch 39 drift time > 800
|
|
close-up of tracks with ch 37 drift time > 800
|
resolution for each channel
|
Drift time fit, ch 30, hit threshold 6#sigma
Resolution for ch30, hit threshold 6#sigma
Resolution vs drift radius ch30, >80% hits on track
|
Resolution ch30, >80% hits on track
|
Resolution ch30, drift radius > 5mm, >80% hits on track
|
Resolution for ch30, hit threshold 6#sigma, Garfield tables for 51% Ar, 49% CO2
Resolution vs drift radius ch30, >80% hits on track
|
Resolution ch30, >80% hits on track
|
Resolution ch30, drift radius > 5mm, >80% hits on track
|
x and y resolution for ch34, driftradius>5mm, hit threshold 6#sigma, Garfield tables for 51% Ar, 49% CO2
Resolution ch34, drift radius > 5mm, >80% hits on track
|
X resolution ch34, drift radius > 5mm, >80% hits on track
|
Y resolution ch34, drift radius > 5mm, >80% hits on track
|
same again after moving tabled position of wire 34 from x,y to x-180um,y
Resolution ch34, drift radius > 5mm, >80% hits on track, x34-180um
|
X resolution ch34, drift radius > 5mm, >80% hits on track, x34-180um
|
Y resolution ch34, drift radius > 5mm, >80% hits on track, x34-180um
|
Assumed straw radius of 10mm (not real 8mm) for Garfield x-t tables
Resolution vs drift radius ch34, >80% hits on track, 10mm Garfield r
|
Resolution ch34, >80% hits on track, 10mm Garfield r
|
Resolution ch34, drift radius > 5mm, >80% hits on track, 10mm Garfield r
|
Resolution vs drift radius ch34, >80% hits on track, 8mm Garfield r
|
Resolution ch34, >80% hits on track, 8mm Garfield r
|
Resolution ch34, drift radius > 5mm, >80% hits on track, 8mm Garfield r
|