Difference between revisions of "Minutes-10-11-2012"

From GlueXWiki
Jump to: navigation, search
Line 20: Line 20:
 
== Production ==
 
== Production ==
  
- Dave: Forth cell of the first package was installed yesterday, today we put a cathode from the fifth cell, tomorrow we plan to finish also the last cell.
+
- Dave: Fourth cell of the first package was installed yesterday, today we put a cathode from the fifth cell, tomorrow we plan to finish also the last cell.
We are using the six spare cathodes made at the end of the production.
+
We are using the six spare cathodes made at the end of the production. The last cathode (#58) to finish the package needs the cards glued on it. Wire frame #29 is ready, except wire deadening. Wire frame #30 is on the stringing table, we will have Casey and Mike later in the month to string it. 
 +
 
 +
- Now we are at most four people at Blue Crab: Dave, Anatoly, Vlad, and Lubomir. Moving the cathodes with the vacuum fixture require four people.
  
 
== Cathode corrosion ==
 
== Cathode corrosion ==
  
- SEM analyses of Viton+Apiezon samples shown above: without cleaning, cleaned with alcohol, and with xylene (latests results). The carbon goes down with the cleaning and the rest is just copper. How to explain the dark color on the copper: either the method is not sensitive to what is there or (Bill) we still see the carbon that is difficult to clean. Olga will make pictures with the high-resolution optical microscope.  
+
- Vlad showed results of the tests in the vacuum chamber at high temperature (~100degC) where all the samples (cathode traces 0.5mm wide) have wires soldered and he measures their resistance continuously without opening the chamber. Using gas, the EPDM sample showed >1MOhm resistance after 8-10 days, which translated to room temperature is ~100 days or more depending on the activation energy. No changes in the Viton, and Viton+Apiezon resistance after 15 days. New tests started with air at 100degC and 100% humidity. No effects yet after 3.5 days.
 +
 
 +
- Eugene: humidity doesn't seem to be such important factor; if that's the case the gas itself can contribute significantly to the corrosion?< But then one has to explain the Viton/ EPDM difference, and why the corrosion happens at the O-ring. Eugene proposed to do also experiment in air but at low humidity. In the moment the priority of the studies is to investigate the Viton+Apiezon samples at worse possible conditions and then translate the results to the hall conditions.
  
 
== Engineering ==
 
== Engineering ==
  
- Bill made plots for the TDR, including the fiducialization that Simon needs also for the simulations.
+
- Bill  
  
 
== Electronics ==
 
== Electronics ==

Revision as of 17:31, 11 October 2012

October 11, 2012 FDC meeting

Agenda

  1. Production Construction Tracking (Dave)
    • Status
    • First package assembly
  2. Corrosion test results (Vlad)
  3. Engineering (Bill)
  4. Electronics (Chris, Nick)
  5. Third package tests FDC E-log (Beni)
  6. TDR, pages 132-146 (Lubomir)
  7. Other