Line 26: | Line 26: | ||
** Changed track candidate algorithm structure (removes memory explosion & slow reconstruction): Decreased %events with no track candidates from ~12% to ~4%. | ** Changed track candidate algorithm structure (removes memory explosion & slow reconstruction): Decreased %events with no track candidates from ~12% to ~4%. | ||
** Upgraded to newest Kalman Filter code (includes fix for broken tracks): Decreased %events with no time-based tracks from ~12% to ~4%. | ** Upgraded to newest Kalman Filter code (includes fix for broken tracks): Decreased %events with no time-based tracks from ~12% to ~4%. | ||
− | ** Truncated track stepping once track turns back inwards towards the target (Δr < 0.0): Decreased %events with no time-based tracks from ~12% to ~4%. | + | ** Truncated track stepping once track turns back inwards towards the target (Δr < 0.0) (also changed minimum pion p to 50 MeV/c): Decreased %events with no time-based tracks from ~12% to ~4%. |
* # Reconstructed Tracks / Event: | * # Reconstructed Tracks / Event: |
Revision as of 02:26, 7 May 2012
Track Candidate Reconstruction Sampling
- All events have one π+ thrown at p = 150 MeV/c, θ = 90 degrees, φ = random.
- These are identical to those presented at the 04/25/2012 Tracking Software meeting.
Event # | Hits (CDC & Truth) | Current (04/08/12) Code Track Candidates | Spiral Code Track Candidates |
---|---|---|---|
Event 1 | |||
Event 2 | |||
Event 3 | |||
Event 294 |
Spiral Fitting - Histograms
- Improvements from last time (04/25/2012):
- Changed track candidate algorithm structure (removes memory explosion & slow reconstruction): Decreased %events with no track candidates from ~12% to ~4%.
- Upgraded to newest Kalman Filter code (includes fix for broken tracks): Decreased %events with no time-based tracks from ~12% to ~4%.
- Truncated track stepping once track turns back inwards towards the target (Δr < 0.0) (also changed minimum pion p to 50 MeV/c): Decreased %events with no time-based tracks from ~12% to ~4%.
- # Reconstructed Tracks / Event:
- NOTE: Hit selectors disabled for wire based & time based fits, except for "SVN Code": instead use hits from track candidates (and ignore hits after spiral turn back inwards)