Difference between revisions of "CDC prototype fADC data"
From GlueXWiki
Line 53: | Line 53: | ||
|width="300pt"| | |width="300pt"| | ||
[[Image:fit2411.png|thumb|300px]] | [[Image:fit2411.png|thumb|300px]] | ||
− | |||
|width="300pt"| | |width="300pt"| | ||
[[Image:fit704.png|thumb|300px]] | [[Image:fit704.png|thumb|300px]] | ||
Line 66: | Line 65: | ||
|width="800pt"| | |width="800pt"| | ||
[[Image:1exp-int.png|thumb|800px ]] | [[Image:1exp-int.png|thumb|800px ]] | ||
+ | |} | ||
+ | {| border="0" cellpadding="2" | ||
+ | |width="300pt"| | ||
+ | [[Image:int133.png|thumb|300px]] | ||
+ | |width="300pt"| | ||
+ | [[Image:int147.png|thumb|300px]] | ||
+ | |- | ||
+ | |width="300pt"| | ||
+ | [[Image:int167.png|thumb|300px]] | ||
+ | |width="300pt"| | ||
+ | [[Image:int266.png|thumb|300px]] | ||
+ | |width="300pt"| | ||
+ | [[Image:int428.png|thumb|300px]] | ||
+ | |- | ||
+ | |width="300pt"| | ||
+ | [[Image:int334.png|thumb|300px]] | ||
+ | |width="300pt"| | ||
+ | [[Image:int2411.png|thumb|300px]] | ||
+ | |width="300pt"| | ||
+ | [[Image:int704.png|thumb|300px]] | ||
|} | |} |
Revision as of 11:27, 28 October 2011
Data from cosmics with 50/50 gas, 2100V
Fit attempt 1
Use pedestal before peak, max peak amplitude, end of peak. End of peak is 2 samples after the last sample where ADC value is at least 20 less than the previous sample. Function fitted to many events for range end-of-peak to final sample was pedestal + 0.14 * maxamp * exp(-0.0056*(x-endpeak)) where x=sample number. The constants were the mean values of the fitted function parameters.
Fit attempt 2
Use pedestal before peak, end of peak, integrated peak. Function fitted to many events for range end-of-peak to final sample was
pedestal + 0.0074 * integratedpeak * exp(-0.0056*(x-endpeak))
where x=sample number. The constants were the mean values of the fitted function parameters.