Difference between revisions of "CDC prototype fADC data"

From GlueXWiki
Jump to: navigation, search
Line 2: Line 2:
  
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
|width="400pt"|
+
|width="300pt"|
[[Image:event133.png|thumb|400px]]
+
[[Image:event133.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:event147.png|thumb|400px]]
+
[[Image:event147.png|thumb|300px]]
 
|-
 
|-
|width="400pt"|
+
|width="300pt"|
[[Image:event167.png|thumb|400px]]
+
[[Image:event167.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:event266.png|thumb|400px]]
+
[[Image:event266.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:event428.png|thumb|400px]]
+
[[Image:event428.png|thumb|300px]]
 
|-
 
|-
|width="400pt"|
+
|width="300pt"|
[[Image:event334.png|thumb|400px]]
+
[[Image:event334.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:event2411.png|thumb|400px]]
+
[[Image:event2411.png|thumb|300px]]
 
|-
 
|-
|width="400pt"|
+
|width="300pt"|
[[Image:event704.png|thumb|400px]]
+
[[Image:event704.png|thumb|300px]]
 
|}
 
|}
  
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
|width="400pt"|
+
|width="300pt"|
[[Image:run_31716_maxamp20.png|thumb|400px|Histogram of first max in amplitude exceeding pedestal + 5 sigma ]]
+
[[Image:run_31716_maxamp20.png|thumb|300px|Histogram of first max in amplitude exceeding pedestal + 5 sigma ]]
 
|}
 
|}
  
Line 32: Line 32:
  
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
|width="900pt"|
+
|width="800pt"|
[[Image:1exp.png|thumb|900px ]]
+
[[Image:1exp.png|thumb|800px ]]
 
|}
 
|}
  
 
{| border="0" cellpadding="2"
 
{| border="0" cellpadding="2"
|width="400pt"|
+
|width="300pt"|
[[Image:fit133.png|thumb|400px]]
+
[[Image:fit133.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:fit147.png|thumb|400px]]
+
[[Image:fit147.png|thumb|300px]]
 
|-
 
|-
|width="400pt"|
+
|width="300pt"|
[[Image:fit167.png|thumb|400px]]
+
[[Image:fit167.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:fit266.png|thumb|400px]]
+
[[Image:fit266.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:fit428.png|thumb|400px]]
+
[[Image:fit428.png|thumb|300px]]
 
|-
 
|-
|width="400pt"|
+
|width="300pt"|
[[Image:fit334.png|thumb|400px]]
+
[[Image:fit334.png|thumb|300px]]
|width="400pt"|
+
|width="300pt"|
[[Image:fit2411.png|thumb|400px]]
+
[[Image:fit2411.png|thumb|300px]]
 
|-
 
|-
|width="400pt"|
+
|width="300pt"|
[[Image:fit704.png|thumb|400px]]
+
[[Image:fit704.png|thumb|300px]]
 
|}
 
|}

Revision as of 16:59, 27 October 2011

Data from cosmics with 50/50 gas, 2100V

Event133.png
Event147.png
Event167.png
Event266.png
Event428.png
Event334.png
Event2411.png
Event704.png
Histogram of first max in amplitude exceeding pedestal + 5 sigma

Fit attempt 1
Use pedestal before peak, max peak amplitude, end of peak. End of peak is 2 samples after the last sample where ADC value is at least 20 less than the previous sample. Function fitted to many events for range end-of-peak to final sample was pedestal + 0.14 * maxamp * exp(-0.0056*(x-endpeak)) where x=sample number. The constants were the mean values of the fitted function parameters.

1exp.png
Fit133.png
Fit147.png
Fit167.png
Fit266.png
Fit428.png
Fit334.png
Fit2411.png
Fit704.png