Difference between revisions of "CDC prototype fADC data"

From GlueXWiki
Jump to: navigation, search
Line 26: Line 26:
 
|width="400pt"|
 
|width="400pt"|
 
[[Image:run_31716_maxamp20.png|thumb|400px|Histogram of first max in amplitude exceeding pedestal + 5 sigma ]]
 
[[Image:run_31716_maxamp20.png|thumb|400px|Histogram of first max in amplitude exceeding pedestal + 5 sigma ]]
 +
|}
 +
 +
Fit attempt 1<br/>
 +
Use pedestal before peak, max peak amplitude, end of peak - this is the first sample with contents > 20 less than its neighbor, starting with the last sample and working forwards. Function fitted to many events for range end-of-peak to final sample  was pedestal + 0.14 * maxamp * exp(-0.0056*(x-endpeak))
 +
 +
{| border="0" cellpadding="2"
 +
|width="400pt"|
 +
[[Image:1exp.png|thumb|400px ]]
 
|}
 
|}

Revision as of 16:01, 27 October 2011

Data from cosmics with 50/50 gas, 2100V

Event133.png
Event147.png
Event167.png
Event266.png
Event428.png
Event334.png
Event2411.png
Event704.png
Histogram of first max in amplitude exceeding pedestal + 5 sigma

Fit attempt 1
Use pedestal before peak, max peak amplitude, end of peak - this is the first sample with contents > 20 less than its neighbor, starting with the last sample and working forwards. Function fitted to many events for range end-of-peak to final sample was pedestal + 0.14 * maxamp * exp(-0.0056*(x-endpeak))

1exp.png