Difference between revisions of "CDC prototype more on timing"
From GlueXWiki
Line 37: | Line 37: | ||
|width="450pt"| | |width="450pt"| | ||
[[Image:run_31716_track54_le2_p3_thr6_z20.png|thumb|450px|6 sigma, p=3]] | [[Image:run_31716_track54_le2_p3_thr6_z20.png|thumb|450px|6 sigma, p=3]] | ||
+ | |} | ||
+ | |||
+ | |||
+ | Previous best resolutions for 50/50 gas mix:<br/> | ||
+ | Resolutions for ch20 ignoring hits before tzero, using 50/50 mix in Garfield and wire diameter of 17.8um instead of 20um, 2100V (left) and 2050V (right). | ||
+ | {| border="0" cellpadding="2" | ||
+ | |width="250pt"| | ||
+ | [[Image:run_31716_5050_tz7_tfix1000_xchunks1.png|thumb|250px|50/50 Ar/CO2 gas mix Resolution vs fitted drift distance, hit thr=4sigma dt=7ns hits before tzero ignored]] | ||
+ | |width="250pt"| | ||
+ | [[Image:run_31721_5050_tz10_tfix1000_xchunks1.png|thumb|250px|50/50 Ar/CO2 gas mix Resolution vs fitted drift distance, hit thr=4sigma dt=10ns hits before tzero ignored]] | ||
|} | |} |
Revision as of 10:22, 24 October 2011
Current analysis code procedure:
- Calculate s.d. of pedestal for first 100 samples, 100 events, save for later use (sigma)
For each event...
- Calculate mean pedestal over 100 samples ending 10 samples before the trigger time (every 4th of these samples also works)
- Search forward for sample x where adc value > high threshold n1 sigma
- Step back p samples to sample x-p, take adc value of sample x-p to be local pedestal value
- Subtract local pedestal value from a number (10+p) of samples starting at sample x-(p+5) to the LE algo for unsampling
- Search through unsampled data, start with last sample (highest adc value) search backwards until adc value < low threshold n2 sigma
- Calculate time where interpolated unsampled data cross n2 sigma, and add to time of sample x-p, this is the estimated drift time.
Unsampled adc values (z) using different values for p (local pedestal lead time ahead of first/high threshold crossing) for high threshold of 5 sigma. x-axis=0 corresponds to sample x-p-4.2, x-xaxis=5 corresponds to 1+x-p-4.2, etc. 5 unsampled values per 8ns sample, all events for ch17 (central straw) included (no tracking)
High threshold 4 sigma
High threshold 6 sigma
Previous best resolutions for 50/50 gas mix:
Resolutions for ch20 ignoring hits before tzero, using 50/50 mix in Garfield and wire diameter of 17.8um instead of 20um, 2100V (left) and 2050V (right).