BCAL
- Readout and monitoring of temperature sensors
- Estimated ~10 input channels (from Elton)
- Control of 70V Bias LV channels on SiPMs
- Estimated 144 channels ?????
- Control of 5V LV on amplifiers
- Estimated 96 channels ??????
FCAL
- Control of HV on CW PMTs (IU is taking care of most of this)
- Estimated 2800 channels (from Matt)
- Control and monitor thresholds
- Estimated 2800 channels (from Matt)
FDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 130 channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 64 channels (WIENER) or 77 channels (CAEN) (Doc. 966-v4)
CDC
- Readout and monitoring of of temperature sensors :
- Estimated ~10 input channels (from Lubomir and Beni)
- Control of HV channels CAEN A1535
- Estimated 24 negative and 24 positive channels (Doc. 967-v6)
- Control of LV on preamp cards (MPV 8008 or CAEN A1518)
- Estimated 16 channels (WIENER) or 18 channels (CAEN) (Doc. 966-v4)
Tagger
- Control of HV channels
- Estimated 310 channels (Fernando's table)
- Motion control
- 3 motors to control the microscope
Beamline
- Goni control
- control 3 axis of motion of to position the crystal and it's orientation
- Harps
- 2 harps, one before the radiator, another one before the beam dump
- control 2 axis of collimator motion
- control the position of the total absorption counter
Pair Spectrometer
- Control pair spectrometer magnet
- Serial port communication to the power supply
- 1 Gauss-meter to B-field measurement
- HV/LV control
- Approximately 20 channels, too early to decide
- Positioning of the converter
- 1 axis motion