The following plot is taken from our NIM article that shows the chamber efficiency as a function of the high voltage setting for various gas mixtures. As can be seen, for the optimal gas mixture | The following plot is taken from our NIM article that shows the chamber efficiency as a function of the high voltage setting for various gas mixtures. As can be seen, for the optimal gas mixture | ||
(around 50/50), the plateau starts at about 2100 V and there is no efficiency below around 1900V. | (around 50/50), the plateau starts at about 2100 V and there is no efficiency below around 1900V. | ||
Line 23: | Line 23: | ||
|- | |- | ||
|} | |} | ||
− | |||
== Minutes == | == Minutes == |
Revision as of 16:52, 11 June 2010
Meeting Time and Place
Monday June 11, 2010 at 10:00am At Jefferson Lab, the meeting will be held in room F326-327
Connections
To connect from the outside, please use ESNET
1.) ESNET: 8542553
2.) Phone:
+1-800-377-8846 : US
+1-888-276-7715 : Canada
+1-302-709-8424 : International
then enter participant code: 77438230# (remember the "#")
Agenda
Efficiency Plots for the CDC
The following plot is taken from our NIM article that shows the chamber efficiency as a function of the high voltage setting for various gas mixtures. As can be seen, for the optimal gas mixture (around 50/50), the plateau starts at about 2100 V and there is no efficiency below around 1900V.