Difference between revisions of "RunPeriod-2021-09 Validation"
From GlueXWiki
(→Run list) |
(→Run list) |
||
Line 11: | Line 11: | ||
== Run list == | == Run list == | ||
+ | #Periods | ||
+ | #* period 1, 81113 -> 81120, 150 nA, Summer 2020 HV, FCAL pi0 with FDC & CDC turn off | ||
+ | #* period 2, 81126 -> 81164, 150 nA, Summer 2020 HV - 6V, FCAL pi0 with FDC & CDC turn off | ||
+ | #* period 3, 81221 -> 81123, 150 nA, Fall 2021 ver 1, FCAL pi0 with FDC & CDC turn off | ||
+ | #* period 4, 81262 -> 81267, 200 nA, Fall 2021 ver 2, FCAL pi0 with FDC & CDC turn off | ||
+ | #* period 5, 81331 -> 81342, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on | ||
+ | #* period 6, 81343 -> 81355, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on | ||
+ | #* period 7, 81356 -> 81xxx, 100 nA, Fall 2021 ver 2, medium intensity Be production with FDC & CDC turn off | ||
So far 4.03B events taken | So far 4.03B events taken |
Revision as of 15:42, 3 October 2021
Contents
Monitoring Team
Sasha: PS
Tyler: Tagger
Igal: FCAL
Drew: CCAL
Run list
- Periods
- period 1, 81113 -> 81120, 150 nA, Summer 2020 HV, FCAL pi0 with FDC & CDC turn off
- period 2, 81126 -> 81164, 150 nA, Summer 2020 HV - 6V, FCAL pi0 with FDC & CDC turn off
- period 3, 81221 -> 81123, 150 nA, Fall 2021 ver 1, FCAL pi0 with FDC & CDC turn off
- period 4, 81262 -> 81267, 200 nA, Fall 2021 ver 2, FCAL pi0 with FDC & CDC turn off
- period 5, 81331 -> 81342, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on
- period 6, 81343 -> 81355, 50 nA, Fall 2021 ver 2, low intensity Be production with FDC & CDC turn on
- period 7, 81356 -> 81xxx, 100 nA, Fall 2021 ver 2, medium intensity Be production with FDC & CDC turn off
So far 4.03B events taken
Note on monitoring launches
PS Calibration
Tagger Calibration
FCAL Calibration
CCAL Calibration
2021 Run List
Run Lists
AMO | 81113,81114,81118,81119,81120,81126,81127,81128,81129,81130,81131,81132,81133,81134,81159,81164,81221,81222,81223,81261,81262,81263,81264,81265,81266,81267 |
Monitoring Launch Checks
Team members
- BCAL: Tolga Erbora, Zisis Papandreou/Regina
- CDC: Naomi Jarvis/CMU, Jason Barlow
- FCAL: Susan Schadmand
- CCAL: ?
- FDC: Churamani Paudel
- PS/PSC: Kevin Luckas
- TAGH/TAGM: Gabriel Rodriguez
- TOF: Edmundo Barriga
- SC: Rupesh Dotel
- Timing: Mariana Khachatryan
- Analysis: Lawrence Ng
Detector/Calibration Experts
- BCAL: Mark Dalton, Zisis Papandreou, Elton Smith
- CDC: Naomi Jarvis, Beni Zihlmann
- FCAL: Mark Dalton, Malte Albrecht, Rebecca Barsotti, Igal Jaegle
- CCAL: Alex Somov, Drew Smith
- FDC: Lubomir Pentchev
- PS/PSC: Alex Somov, Olga Cortes
- TAGH: Alex Somov, Olga Cortes
- TAGM: Richard Jones
- TOF: Paul Eugenio, Beni Zhilmann
- SC: Mark Ito
- Timing: Sean Dobbs
- Analysis: Alexander Austregesilo, Sean Dobbs
Batch 1
Runs 81113 - 81352
Detector systems used are FCAL,TAGM,TAGH,CCAL,BCAL,PS. No Magnetic field. SC, CDC, FDC were not used
- monitoring spreadsheet blank version
- Plot Browser
- Reference Plots
- Monitoring Spreadsheets