Difference between revisions of "Tracking-6-17-2021"
From GlueXWiki
(→Agenda) |
(→Minutes) |
||
Line 18: | Line 18: | ||
= Minutes = | = Minutes = | ||
+ | # Tracking | ||
+ | ## [https://halldweb.jlab.org/wiki/images/5/5f/20210617.pdf MilleKs alignment] | ||
+ | # Detector related reports | ||
+ | #* FA125 | ||
+ | #**Cody liaised with the TI authors to make the standalone trigger generate a trigger from the TI using the busy line. The standalone trigger is now usable. | ||
+ | #**For the CDC & FDC, he has a firmware version ready to test, hoping that the itrigger inconsistencies will have gone. | ||
+ | #* CDC | ||
+ | #** The EPSCI group's AIEC project is producing good results for the gain calibrations and now moving on to look at time to distance. | ||
+ | #** The dE/dx from the latest analysis launch looks really nice, the thumbnail histogram (click to enlarge) shows K+ dE/dx from ver 46 trees with kin fit chisq < 10 but no other cuts. [[Image:Kp_cdc_kfonly.png|thumb|x100px|CDC dE/dx for K+]] |
Revision as of 14:49, 17 June 2021
- Instructions for Bluejeans meeting connection
- Meeting ID: 290664653
- To join via a Web Browser, go to the page [1] https://bluejeans.com/290664653.
Thu 6/17/2021 2pm
Agenda
- Tracking
- Detector related reports
- FA125
- Cody liaised with the TI authors to make the standalone trigger generate a trigger from the TI using the busy line. The standalone trigger is now usable.
- For the CDC & FDC, he has a firmware version ready to test, hoping that the itrigger inconsistencies will have gone.
- CDC
- The EPSCI group's AIEC project is producing good results for the gain calibrations and now moving on to look at time to distance.
- The dE/dx from the latest analysis launch looks really nice, the thumbnail histogram (click to enlarge) shows K+ dE/dx from ver 46 trees with kin fit chisq < 10 but no other cuts.
- FDC
- FA125
- GEM-TRD
- Other
Minutes
- Tracking
- Detector related reports
- FA125
- Cody liaised with the TI authors to make the standalone trigger generate a trigger from the TI using the busy line. The standalone trigger is now usable.
- For the CDC & FDC, he has a firmware version ready to test, hoping that the itrigger inconsistencies will have gone.
- CDC
- The EPSCI group's AIEC project is producing good results for the gain calibrations and now moving on to look at time to distance.
- The dE/dx from the latest analysis launch looks really nice, the thumbnail histogram (click to enlarge) shows K+ dE/dx from ver 46 trees with kin fit chisq < 10 but no other cuts.
- FA125